This table generates, uses, and can radiate radio 
frequency energy and, if not installed and used in 
accordance with the instructions, may cause harmful 
interference to other devices in the vicinity. However, 
there is no guarantee that interference will not occur in 
a particular installation. Harmful interference to other 
devices can be determined by turning this table on 
and off. Try to correct the interference using one or 
more of the following: reorient or relocate the receiving 
device, increase the separation between the 
equipment, connect the table to an outlet on a 
different circuit from that which the other device(s) are 
connected, and consult Coinfycare for help. 
Unplug the table from the power supply before starting 
cleaning or any types of maintenance operations. 
The table should be kept out of the reach of children 
when there is no adult supervision. 
The table is designed for discontinuous interval 
operation, so the continuous running time of the motor 
should never exceed 2 minutes. Should this happen, 
damage may occur due to overheating of the 
electronics. 
Always use original accessories and spare parts 
provided by your dealer. 
Always cover the table with a towel, disposable paper 
or a cover and change it for each user, thus ensuring 
correct hygiene and extending the useful life of the 
upholstery. 
Only connect the table to a properly installed and 
grounded outlet. The local mains voltage must 
correspond to the technical data of the device. 
The power outlet should be accessible in case 
the table needs to be quickly unplugged at any 
given time. Always pull the plug and not the mains 
cable. 
Unplug the table from the power supply before starting 
cleaning or any types of maintenance operations. 

 

 

TECHNICAL SPECIFICATIONS 

Product dimensions 

Length: 1900mm 
Width: 600mm 
Lifting range of bed surface: 565-980mm 

If the electrical supply cable is defective, 
disconnect the table immediately and inform your 
dealer or a specialized technician. 
Position the power cord properly so that it cannot be 
tripped over. 
Unplug the power cord from the mains if the table is 
not going to be used for a long period of time. 
If you detect any abnormality in the operation of the 
table, consult your dealer or a specialized technician. 
Never manipulate any electrical part or open or 
repair any part of the table. 
Only your dealer or a specialized technician should 
repair the table. 
Never touch the table or the power cord with wet 
hands. 
Never place your hands or any other part of your 
body in any hole or void on the table while it is in 
operation. 
Make sure there are no objects in the space under 
the table that could cause collisions or entrapment 
during operation. 
Make sure that your feet are not resting on the 
peripheral foot bar or foot control during treatment 
and especially when sitting near the table. This 
could create a dangerous situation where your leg 
is caught between the section and the peripheral 
foot bar or floor surface. 
Take into account the weight distribution on the 
table when working. The weight must be distributed 
along the table without concentrating on its ends to 
maintain the correct stability. 
You should not sit on the head and foot sections. If 
you do,there is a danger of tipping and table damage. 

 

 

PLACEMENT IN THE 
WORKPLACE 

The table has four wheels to facilitate movement 
to the place where it will be used. 

Содержание EL35

Страница 1: ...EL35 Electrical Podiatry Chair ...

Страница 2: ...ulation of medical devices EU 2017 745 and with the following standards EN 60601 1 2006 A1 2013 AC 2014 Medical electrical equipment Part 1 General Requirements for Basic Safety and Essential Performance IEC EN 60601 2 52 2009 A1 2015 clause 201 9 8 3 2 Medical electrical equipment Part 2 52 Particular requirements for basic safety and essential operation of medical tables EN 60601 1 6 2010 A1 201...

Страница 3: ...ys pull the plug and not the mains cable Unplug the table from the power supply before starting cleaning or any types of maintenance operations TECHNICAL SPECIFICATIONS Product dimensions Length 1900mm Width 600mm Lifting range of bed surface 565 980mm If the electrical supply cable is defective disconnect the table immediately and inform your dealer or a specialized technician Position the power ...

Страница 4: ...s in the space under the table before any operation The table should be placed at the lowest level to reduce the risk of injury caused by the patient falling off the table when unattended Adjustment of the tail section As shown in Figure below turn the control lever in the direction indicated by the arrow to adjust the tail section between 0 80 when adjusted to the desired angle release the contro...

Страница 5: ...e direction shown by the arrow to adjust the angle of the head section When adjusted to the desired angle release the control lever to be parallel to the chair surface and the chair surface angle will be locked Figure 8 Figure 9 Pins Figure 7 Figure 8 Figure 10 Installation of adjustable extension pad Insert the square tube of the extension pad into the frame of the chair section adjust it to an a...

Страница 6: ...heck the wheel immobilization system RECYCLING If you need to dispose of the table or any of its parts or accessories consult and respect the laws and regulations applicable to waste management and protection of the environment WARRANTY This warranty shall remain in effect for 5 years 60 months for the structure and 3 years 36 months for the base frame and motor from the date of original consumer ...

Страница 7: ...gas SHUTDOWN PROCEDURE Adjust the bed to a suitable position to ensure that the patient is safely left then turn off the power Contraindication Please note that our beds are not sterilized Please do not use them according to aseptic standards CONTACT Applicant company name after sales service unit Huangshan Jinfu Medical Instrument Co Ltd Domicile production address No 17 Qiliting Qimen County Hua...

Страница 8: ...JF EMN 2022V 01 www coinfycare com ...

Отзывы: