2
1
3
4
5
4 Planning the module area
Conergy SunTop Trapeze
Installation manual
7
ENGLISH
4 Planning the module area
The following gives the spacing of the roof mounts for in-
stalling modules that are in a portrait orientation. The spac-
ing for landscape orientation can be found in section 8. The
trapezoidal fixation must be mounted at specific distances
depending on the material, thickness of the trapezoidal
sheet metal, the spacing of the high bead of the corruga-
tion, consideration of the edge area and the further general
conditions* (a tool is used for the design).
Taking the above mentioned points into consideration,
the trapezoidal fixation must be placed so that they are as
close as possible to the module clamps.
When positioning, please note that
• the given dimensions are guidelines.
• the dimensions of the trapezoidal sheet metal and the
high bead of the corrugation define the true horizontal
spacing.
* A design in accordance with the local conditions according to
Eurocode 1-DIN 1055 / Eurocode 9-DIN EN 1999-1-1 is required.
1. Height of the module field: number of modules in the vertical x module height
2. Width of the module field: Number of modules in the horizontal x (module width + 19 mm) + 50 mm
3. Spacing of the guide rails in the vertical (in accordance with the clamping points defined by the module manufacturer): approx. the quarter
points of the modules = 1/2 x module height
4. Spacing of the trapezoidal fixations in the portrait orientation: according to the plan, depending on the trapezoidal sheet metal and the
structural
analysis*
5. Spacing between the modules = 17 – 19 mm
Содержание SunTop Trapeze
Страница 1: ...Conergy SunTop Trapeze www conergy com Installation manual ...
Страница 23: ......