Installation Instructions
Expansion Module and Expansion Element
Program 0815
MV0815-0005a-EN
www.conductix.com translated document
page 14 of 26
The additional hanger clamps must be placed so that collisions with other components cannot
occur during expansion of the system (see section 2.3.3.1 in MV0185-0007). When installing ex-
pansion modules, a different permitted minimum distance of 100 mm applies between the hanger
clamp and other system components, which can be appropriately reduced due to the concept of
expansion modules with interdivisional cable guides.
Fig. 13: Example of potential overlap of the conductor rail
A = Additional hanger clamp is required
B = Hanger clamps are offset in the direction of installation
Fig. 14: System after offsetting the hanger clamps
If there is an appropriate gap in the system, the hanger clamps used for installation of the expansion module can be
offset to the front.
In this case, an additional hanger clamp must be placed after the expansion module for additional installation, so that
the maximum spacing between two hanger clamps of 500 mm is not exceeded.
Fig. 15: Potential gap between expansion module and end of the conductor rail already installed
If the expansion module should specifically be installed at a fastening point in the system, it is always possible to leave
all hanger clamps and to cut off the conductor rail to the correct dimension.