Operating Instructions
Insulated Conductor Rail System
SinglePowerLine Program 0813
BAL0813-0007-EN
www.conductix.com
translated document
page 97 of 108
10
Troubleshooting
10.1
Safety
Wear recommended protective equipment:
WARNING!
Danger of injury due to improper troubleshooting!
Improper troubleshooting can result in serious injury to person and property.
→
Contact the manufacturer in case of malfunction.
→
Allow troubleshooting to be conducted only by personnel from or authorized by the
manufacturer.
The faults that, to Conductix-Wampfler's best knowledge, tend to arise are listed in the following table (see Section 10.2) together
with their corresponding corrective measures.
CAUTION!
Before working on these components!
→
Switch off the power supply to the
conductor rail system
according to the 5
Safety Rules
and secure it against switching on again
. For the 5 Safety
Rules, see Section 2.5.
DANGER!
Risk of death due to electrical shock!
Contact with components carrying electrical power can lead to death or severe injury due to
electrical shock. Danger of injury due to shock reactions, falling or being thrown across the room
due to electrical shock.
→
Disconnect all line feeds from the voltage supply.
→
When decommissioning, check whether a voltage is still present in the components and
take measures where necessary.
→
The hazard zone must be enclosed by the customer or protected through distance.
→
The customer must provide grounding for metallic components.
→
The customer must provide protective devices.
→
Ensure that there is sufficient stability in the area.
→
If a conductor rail heating is available, this must also be switched to a voltage-free state.
Care must be taken to ensure that each individual heating circuit is voltage-free.