Operating Instructions
Insulated Conductor Rail System
SinglePowerLine Program 0813
BAL0813-0007-EN
www.conductix.com
translated document
page 50 of 108
6.4.3.1
6.4.3.2
Mount hanger clamps
NOTE!
The maximum tightening torques must not be exceeded (14 Nm for a standard hanger clamp
with steel nut). Too high tightening torques will damage the hanger clamp.
NOTE!
The hanger clamp fastening must be adapted to the respective application!
The fastening elements are designed for standard fastening applications. For safety-critical fastenings,
special on-site interfaces (e.g., deviating through-hole geometry or other restrictions affecting the
fastening) and/or increased requirements (e.g., vibration), the fastening must be adapted to the
respective application (e.g., by means of additional screw locking with Loctite 242). The system
manufacturer is responsible for the evaluation.
Required tools:
◼
Open-end wrench, SW17
◼
Mounting comb (Order No.: 081046*)
The hanger clamps are available in versions with square nuts for mounting in support arms/C-rails (see Fig. 47) or hexagon nuts
(see Fig. 48) as well as with or without an insulator (see Fig. 12). A version with a hexagon nut is recommended for current collector
insertion from the side.
Insulators are required for indoor applications with high levels of pollution and outdoor applications and allow a rated voltage of up to
1000 V (with current collector insertion from below).
Fig. 47: Hanger clamp with square nut
Fig. 48: Hanger clamp with hexagon nut