Condari Rangecraft RPB 100L-1 Скачать руководство пользователя страница 2

 

Installation instructions Rangecraft Rangehoods  

Fitted with Plasma-Norm Filter 

 

IMPORTANT INFORMATION 

 
Rangecraft rangehoods can be installed at 600mm above the trivets of a gas hotplate.  
Over an induction cooktop the minimum should be 750mm. 
  

1.  The installation of Rangecraft Rangehoods must comply with the information in this booklet. 

Rangecraft  Rangehoods are designed and made to work efficiently over most  domestic 
cookware available on the Australian market. 

2.  It is necessary to allow electrical disconnection of the Rangehood after installation. 

This may be achieved by either. 

a.  Installing a power point to an accessible area for the Rangehood. 
b.  Incorporating a wall switch to the fixed wiring that supplies the Rangehood 

3.  The installation and fitting of the rangehood and plasma filter should be done in such a way 

that will allow the unit to be removed if service is required. Additional costs incurred in the 
removal of wall tiles, damage to walls or bench tops are not covered by warranty. 

4. 

WARNING:

 Incorrect venting will result in additional noise and a reduction in efficiency.  

a.  Exhaust air must not be discharged into any chimney or flue, which may carry 

combustible products from other sources. 

b.  Do not discharge the airflow from the rangehood into a flue used for exhausting fumes 

from burning gas or fuel; 

c.  For Rangehood cleaning Instructions please refer to page 15.

 

d.  If cleaning is not carried out in accordance with the instructions as listed on page 15, 

there may be an increased risk of fire. 

e.  Some parts of the rangehood may become hot when cooking; 
f.  This appliance is not intended for use by persons (including children) with reduced 

physical, sensory or mental capabilities, or lack of experience and knowledge, unless 
they have been given supervision or instruction concerning use of the appliance by a 
person responsible for their safety. 

5.  Do not flambé under the rangehood. 
6.  If the supply cord is damaged, an authorised service centre or licensed electrician must 

replace it. 

7.  The lights in the rangehoods are LED and come with a night light  
8.  To reduce the risk of fixing screws coming in contact with live parts, do not drill or screw into 

the rangehood. Live wires are encapsulated where possible to prevent user contact. If 
necessary, drill from the inside out and only through single sheet material. 

9.  Rangecraft Rangehoods are not to be used over Barbecues or Grills, if required please contact 

Condari Pty Ltd.  

10. Ensure all requirements are met with gas and electrical regulations and or state authorities. 
11. Rangecraft Rangehoods do not have the capacity to do the job over indoor barbecues,high 

speed gas burners or hotplates with a heat output rating over 40 megajoules. 

12. Please contact Condari Pty Ltd to arrange an authorised technician to replace any cracked 

protective glass shields for the LED lights.   
 

 

 

Содержание Rangecraft RPB 100L-1

Страница 1: ...Rangecraft Rangehood Installation Instructions...

Страница 2: ...uel c For Rangehood cleaning Instructions please refer to page 15 d If cleaning is not carried out in accordance with the instructions as listed on page 15 there may be an increased risk of fire e Som...

Страница 3: ...er RPW 90L RPW 90L RPD 50L RPB 100L Height required inside cabinetry will depend on the Rangecraft Rangehood Return air MUST recirculate back into the same room via a vent in the cabinetry ceiling bul...

Страница 4: ...op front or side of the cabinet it may be orientated vertically or horizontally The return air opening must be no more than 6M away from the Rangehood location and vent into the same room The opening...

Страница 5: ...orm Rangecraft servicing should only be carried out by qualified persons The Carbon Filter should be replaced every 5 years If you notice any lingering odours this could indicate that the Carbon filte...

Страница 6: ...rmount Rangecraft Rangehood Cut Out dimensions MODEL R HOOD SIZE BASE SIZE PROUD MOUNT CUT OUT DIMENSION FLUSH MOUNT CUT OUT DIMENSION RPN 90L 1 264 X 836 290 X 900 270 X 840 293 X 903 RPW 90L 1 294 X...

Страница 7: ...until the base of the Rangehood meets the lower part of cabinetry Do not over tighten screw C 4 Tighten screw A and B by turning clockwise to lock fixing bracket 5 To remove rangehood turn screw A B...

Страница 8: ......

Страница 9: ......

Страница 10: ......

Страница 11: ...to make the Rangehood lighter and easier to handle during install Remove the 6 screw on the plate that the fan is mounted to And carefully remove Fan Plasma assembly 7 Place the four lengths of All th...

Страница 12: ......

Страница 13: ...screws from Fan Plasma mounting plate disconnect Fan Plasma electrical connectors and carefully remove Fan Plasma assembly 9 If you do not have adjustable stands you can cut some temporary timber prop...

Страница 14: ......

Страница 15: ......

Страница 16: ...el oil can also be used to further protect the finish FILTER CLEANING For the best results please clean filters regularly Condari recommends cleaning filters once per month or immediately after heavy...

Страница 17: ...misuse or failure to follow operating instructions where special precautions are detailed for user attention then a charge shall be made for the service call For example With the filters the user is s...

Страница 18: ...tdoor barbecues will have a rating plate on them specifying that they are approved for outdoor use only and also a mega joule rating per burner or a total mega joule rating Rangecraft Rangehoods are d...

Страница 19: ...If no proof of purchase is provided then the service call will be charged at standard rates If proof of purchase is provided at a later date reimbursement of the service call will be made to the cust...

Страница 20: ...aller and the form below is completed The authorised installer also offers a warranty on their workmanship for the same period of 72 months with a guarantee that the installation is in compliance with...

Страница 21: ...salesqld qasair com au SA NT T 1300 360 563 F 03 9482 7011 Email salessa qasair com au TAS T 03 9482 7088 F 03 9482 7011 Email sales qasair com au WA T 08 9242 5387 F 08 9201 0887 Email saleswa qasai...

Отзывы: