background image

2595854-

B

  EN  

2008

Humidification and Evaporative Cooling

READ AND SAVE THESE INSTRUCTIONS

Addendum manual for installation and operation 

for use with Modbus, KNX & Amazon Echo 

(Alexa) interfaces

SPA CONTROL INTERFACES

Modbus

KNX

Amazon Echo

Содержание Amazon Echo

Страница 1: ...Humidification and Evaporative Cooling READ AND SAVE THESE INSTRUCTIONS Addendum manual for installation and operation for use with Modbus KNX Amazon Echo Alexa interfaces SPA CONTROL INTERFACES Modbu...

Страница 2: ...ll be reproduced used or disclosed to others without the written authorisation of Condair Group AG except to the extent required for installation or maintenance of recipient s equipment Liability Noti...

Страница 3: ...RTU 8 3 3 Connection and configuration of the Modbus interface 9 3 4 Modbus Parameters 11 4 KNX Amazon Echo Alexa interface 15 4 1 Connection of the SPA control board to the KNX gateway 15 4 2 Connec...

Страница 4: ...if neglected may cause damage and or malfunction of the unit or other material assets WARNING The catchword WARNING used in conjunction with the general caution symbol designates safety and danger no...

Страница 5: ...he Modbus or KNX interface of the Condair Delta SPA Control Box or the Condair Omega may not be used by persons including children with reduced physical sensory or mental abilities or persons with lac...

Страница 6: ...ta SPA Control Box or the Condair Omega should immediately be shut down and secured against ac cidental power up This can be the case under the following circumstances if the Condair Delta SPA Control...

Страница 7: ...s odd 1 Stop bit even 1 Stop bit Factory setting even 1 Stop bit Baud rate 4800 9600 19200 38400 57600 115200 Data format ABCD big endian BADC big endian swapped CDAB little endian swapped DCBA little...

Страница 8: ...earth Connect all GND together Install bus line separate from supply voltage Topology Daisy chain All devices of the same network need the same settings concerning baud rate and parity Every Modbus de...

Страница 9: ...the Condair Delta SPA Control Box Loosen the two screws of the housing cover and remove the housing cover For the Condair Omega Loosen the screw of the housing cover and remove the housing cover 3 Bre...

Страница 10: ...Condair Omega RJ45 BAT CR 2032 X23 X10 X33 X23 X24 X26 X13 X38 X15 X20 X18 X19 X22 X6 X5 X1 X2 X12 X8 X16 X3 X36 X11 X9 X17 F2 X4 F4 F1 X21 JP1 SW1 JP2 GND D D Fig 3 Connecting the interface cable 6 O...

Страница 11: ...a the SPA display or the integrated web interface under En gineering SPA Control Board Modbus Settings Gateway Setting via SPA display Data Format ABCD big endian Gateway Baudrate 19200 Parity even 1...

Страница 12: ...ime reference date 01 01 2010 0 x s 4136 Time at which the next SPA ses sion for cabin 1 begins 0 86400 s 4472 Remaining time until the next SPA session for cabin 1 begins 0 86400 min 4476 Remaining t...

Страница 13: ...1 480 min 4456 Duration SPA session cabin 1 1 480 min 4460 Start time day timer cabin 2 1 86400 s 6500 Duration day timer cabin 2 1 480 min 6504 Duration SPA session cabin 2 1 480 min 6508 Start Stop...

Страница 14: ...d systems is available which must be mounted outside the corresponding device 4 1 Connection of the SPA control board to the KNX gateway Bt RS485 KNX A B A B Rx GND GND GND Tx RS485 RS232 ETH USB LD1...

Страница 15: ...nect all GND together Install bus line separate from supply voltage Topology Daisy chain All devices of the same network need the same settings concerning baud rate and parity Every Modbus device addr...

Страница 16: ...D GND GND Tx RS485 RS232 ETH USB LD1 LD2 POE SW 24V in LM5 L GND 24 VDC D D GND D D 24 VDC X4 X4 KNX SPA control board 1 Server ID 0 KNX Gateway SPA control board 2 Server ID 1 Fig 5 Connecting the KN...

Страница 17: ...For the Condair Delta SPA Control Box Loosen the two screws of the housing cover and remove the housing cover For the Condair Omega Loosen the screw of the housing cover and remove the housing cover 3...

Страница 18: ...X36 X11 X9 X17 F2 X4 F4 F1 X21 JP1 SW1 JP2 GND D D 24 VDC RJ45 BAT CR 2032 X23 X10 X33 X23 X24 X26 X13 X38 X15 X20 X18 X19 X22 X6 X5 X1 X2 X12 X8 X16 X3 X36 X11 X9 X17 F2 X4 F4 F1 X21 JP1 SW1 JP2 GND...

Страница 19: ...stop bit Data Format ABCD big endian For dual cabin application for medium size cabins 2 SPA control boards must be connected to the gateway For the second SPAcontrol board Server ID 1 the Modbus slav...

Страница 20: ...20 KNX Amazon Echo Alexa interface Setting via web interface...

Страница 21: ...a steam generator or Condair Delta SPA Control Box Part_2 System range 10 0 Basic system settings 10 1 Cabin 1 10 2 Cabin 2 only relevant if a system with dual cabin application is used Part 3 Paramet...

Страница 22: ...Float 16Bit 1 40 20 110 C R W 10 1 4 Humidity setpoint value cabin 1 SpaHumSetpoint_1 Float 16Bit 1 40 5 80 rH R W 10 1 5 Day timer starting time cabin 1 SpaDayTimerStartTime_1 Uint 32Bit 60 36000 0...

Страница 23: ...time of a running SPA session cabin 2 SpaStatusDuration_2 Uint 32Bit 1 60 1 480 min R 10 1 20 Door open closed cabin 1 0 Open 1 Closed IoInDoor_1 Bool 1 0 0 0 n a R 10 1 21 Starting Stopping SPA sessi...

Страница 24: ...ult value Min Max Measur ing unit R W 10 2 23 Timer activated for cabin 2 0 None 1 Day timer time 2 Day timer countdown 3 Week timer SpaStatusTimerActive_2 Uint 32Bit 1 0 0 3 n a R 10 2 24 On Off ligh...

Страница 25: ...on echo alexa integration The following steps show an example of how Alexa speech commands can be defined 1 Connect the KNX Gateway with the connected SPA control boards via an Ethernet cable to your...

Страница 26: ...Protocol Select whether to use a static IP address Factory setting 192 168 0 10 or an IP address assignment from a DHCP server If the protocol is set to DHCP an additional window will appear showing t...

Страница 27: ...r ID 0 KNX Gateway SPA control board 2 Server ID 1 Fig 9 Connecting the KNX Gateway to the Internet Make sure that all network settings IP Gateway DNS under System config Network Interfaces are set co...

Страница 28: ...rface 7 Go to the App Store by clicking the icon 8 Choose Alexa and install this app 9 On the main screen the Amazon App now appears which must be selected 10 Log in with the LogicMachine Cloud Accoun...

Страница 29: ...le Action Voice command Start steam bath session Alexa turn on steam bath Stop steam bath session Alexa turn off steam bath Switch on service light Alexa turn on service light Switch off service light...

Страница 30: ...ynchronization the sync button will show the time of the last synchronization Note Following each modification on the LogicMachine adding removing editing devices the fol lowing steps must be done Syn...

Страница 31: ...alexa amazon com with your Amazon account Under the heading Skills look for LogicMachine 14 Log in with the LogicMachine Cloud Account which was set up in step 4 15 Search for devices in the Alexa acc...

Страница 32: ...NX Amazon Echo Alexa interface Alexa now finds the devices which are listed under point 11 Further example commands for Alexa voice control can be found under http openrb com amazon echo alexa integra...

Страница 33: ...Notes...

Страница 34: ...Notes...

Страница 35: ......

Страница 36: ...Condair Group AG Gwattstrasse 17 8808 Pf ffikon SZ Switzerland Phone 41 55 416 61 11 Fax 41 55 588 00 07 info condair com www condairgroup com CONSULTING SALES AND SERVICE CH94 0002 00...

Отзывы: