5. Main Functions

5.1 SOS

In  emergent  case,  press  SOS  for  3  seconds  to  activate  SOS  alarm. 
Then  the  device  will  send  SOS  SMS  to  preset  SOS  numbers  and 
then dial the numbers in a loop for 3 times until the call is picked up. 
Alarm message will also send to platform. (See command list 7-8)

5.2 Power cut-off alarm

When the electricity supply of device is cut off, it will activate cut-off 
alarm. 

5.3 Low battery alarm

When battery is low, the device will activate low battery alarm.

5.4 Vibration alarm(default OFF)

When  vehicle  vibrates  several  times,  the  vibration  alarm  will  be 
triggered.  If  no  ignition  after  3  minutes  (ACC  OFF),  the  device  will 
send vibration alarm message immediately.(See command list 7-12)

5.5 Voice monitoring

1.

2.

voice

Notice

When MIC and speaker are connected, use pre-set SOS number to

send  command 

  to  the  device.  Device  would  automatically  call 

you  back  in  a  second.  Pick  up  and  monitor  the  voice  inside  the 
vehicle. 

When  MIC  is  connected  while  speaker  is  not,  use  pre-set  SOS 

number  to  dial  the  device,  after  10  seconds,  device  enters  into 
monitoring mode automatically. The caller can hear the 

 inside 

the vehicle. 

 

1.Pre-set SOS number is necessary. 
    Non-SOS number cannot activate this function. 
2.SIM card of device must have caller ID sevice.

JT#

Содержание GT06F

Страница 1: ...GPS Vehicle tracker GT06F User Manual Version V1 1 This user manual has been specially designed to guide you through the functions and features of your GPS vehicle tracker...

Страница 2: ...l time GPS AGPS tracking Track by time interval distance direction change Track through SMS APP Web Remotely fuel power cut off control Voice monitor SOS alarm Geo fence alarm Vibration alarm Movement...

Страница 3: ...8 Speaker 8 1 3 Specifications Frequency GSM 850 900 1800 1900MHz Class 12 TCP IP GPRS 9 36VDC 300mA Operating Voltage Cold Start 35s Location Time Hot Start 2s 10 meters Location Accuracy 20 70 98 5...

Страница 4: ...eady on OFF GSM initializing 0 1s ON 0 1s OFF GSM LED Indicator Green Receive GSM signal normally Connected to GPRS network 0 1s ON 1 9s OFF Steady on No GSM signal OFF 0 1s ON 0 1s OFF Power Status R...

Страница 5: ...tallation 3 1 Install the SIM card Notice SIM should be inserted correctly SIM card should have GPRS service Open waterproof rubber plug Power on off SIM card slot Insert SIM card SIM card s metal fac...

Страница 6: ...negative ACC ignition Relay 5 6 7 8 Red Blue Green Black 5V OUT RX TX GND External power supply Data receiving backup interface Data sending backup interface GND negative 9 Purple ADC 10 11 Orange Yel...

Страница 7: ...nnection Outout control Connection Analog signal Diagram 1 Negative trigger connection car type Positive trigger connection car type Door negative trigger connection Door light Door positive trigger c...

Страница 8: ...ide of oil pump connects to the close end of relay Thick green line 87a and the other side connects to relay s common green thick 30 Notice 12V relay is standard The device is suitable for vehicles wi...

Страница 9: ...ice When device is connected with external power please turn on the battery switch The battery will then connect with the device circuits and its built in battery will be charged If battery is OFF bat...

Страница 10: ...s several times the vibration alarm will be triggered If no ignition after 3 minutes ACC OFF the device will send vibration alarm message immediately See command list 7 12 5 5 Voice monitoring 1 2 voi...

Страница 11: ...otice 1 Only the SOS number can be used to set center number 2 Only the SOS number can be used to delete center number 3 There is only one center number can be set See command list 7 14 5 9 Restore oi...

Страница 12: ...n door is open signal level of door is power voltage when door is closed signal level of door is 0V See command list 7 17 5 12 Analog signal The device can measure car battery s voltage and upload it...

Страница 13: ...To ensure normal network operation please confirm your APN and server setting before login In most countries APN could automatically adapted to local mobile operators If not please send SMS to set th...

Страница 14: ...ce 1 number sequence 2 number sequence 3 SOS D phone number SOS 7 SOS setting TIMER T1 T2 T1 5 18000 seconds ACC ON upload interval default value 10 T2 5 18000 seconds ACC OFF upload interval default...

Страница 15: ...meter E g MOVING ON 200 2 MOVING ON R MOVING OFF 13 Displacement alarm setting default OFF RELAY A A 0 1 0 restore petrol 1 cut off petrol Default value 0 E g RELAY 1 15 Power oil control Set center n...

Страница 16: ...battery Using the GPS tracker in the places that have good signal condition Unable to connect to the network Poor signal Change the installation place Unable to locate Signal shielded or Poor signal T...

Страница 17: ...ions are limited to repair of the defect or replacement the defective part or at its discretion replacement of the product itself 3 Warranty repairs must be carried out by our Authorized Service Centr...

Отзывы: