Installation - Module
1.
Locate a suitable mounting location for the HS-VA3800 Video Amplifier/Combiner
inside the cabinet. Note that the unit can be installed in various positions, the F-
type connectors may face the top or the bottom of the cabinet.
2.
Mount MDA-38R Drop Amplifier on video combiner bracket using the 2 self-tapping
sheet metal screws provided.
3.
Align the two mounting pins with the holes in the back of the cabinet and insert as
indicated in figure 2.
4.
Snap the module in place by pressing both sides towards the back of the cabinet.
5.
Secure the metal bracket to the cabinet using the two screws provided.
Installation - Wiring
The following requirements for installation of coaxial cable must be met for proper oper-
ation of connected equipment.
•
Do
NOT
strip off cable sheathing more than required for proper termination.
•
Do
NOT
kink or knot cable.
•
Do
NOT
crush cable with cable ties.
•
Do
NOT
splice cable.
•
Do
NOT
bend cable at right angles or make any other sharp bends. All cable bends
must have a minimum of a 2" radius.
Figure 2, Installation
Installation - Wiring (Contd.)
1.
Run RG6 coaxial cable from each source/destination through the cabinet
raceway to the HS-VA3800 Amplifier module. Label cables at both ends for
identification. Terminate cables with "F" style connectors.
Note:
Ensure that cable source/destinations are "F" style jacks mounted in an
appropriate wall plate. If using a multiple wall outlet then label the jacks
accordingly.
2.
Connect source/destination ends of the cables to the "F" style jacks. Connect the
terminated drops to the HS-VA3800 Video Amplifer module terminals labelled
"
OUTPUTS
".
3.
Terminate unused output terminals on the HS-VA3800 Video Amplifer module with
75 ohm terminators (not supplied).
4.
Locate a suitable 110VAC receptacle for placement of the wall-mount transformer. If
necessary have a qualified electrician install a 110VAC receptacle close to the panel.
5.
Route RG6 coaxial cable from the power supply at the 110 VAC receptacle into the
cabinet to the HS-VA3800 Video Amplifer module.
6.
Terminate each each end of the coaxial cable using a standard "F" style connector.
Connect the cable to the HS-VA3800 Video Amplifer module terminal labelled '
PWR
- IN
' and to the power supply.
7.
Plug in the power supply and test all connections to confirm proper installation and
termination.
5
HS-CAB1000, HS-CAB3000
or HS-CAB4000 cabinet
1
Mount the MDA-38R Drop Amplifier as
shown to ensure that there is sufficient
clearance for the F-type connectors.
NOTE:
3