Multi-Station 

Remote Alarm

 

INSTALLATION AND OPERATION INSTRUCTIONS

Before Installing or Operating, Read and Comply with These Instructions

Controls Corporation of America

1501 Harpers Road • Virginia Beach, VA 23454

To Order Call 1-800-225-0473 or 757-422-8330 • Fax 757-422-3125

www.concoa.com

 June 2003

Supercedes December 2002

Certified ISO 9001

ADI  8824-C

®

Содержание 529 5310

Страница 1: ...talling or Operating Read and Comply with These Instructions Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 To Order Call 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www...

Страница 2: ...s that are brought to the Output Connector so they may be used to control an external device The status indicator lights are organized into pairs representing the Left Bank and Right Bank of an Autosw...

Страница 3: ...mally closed switch One example of such a device would be the CONCOA telephone dialer PN 5295306 Connections to the Alarm are made through input and output connectors Customer supplied cables are easi...

Страница 4: ...AUTOSWITCH To connect the Multi Station Remote Alarm to an Autoswitch system an interface cable must be made The Autoswitch systems are shipped with a connector that is used for this cable An Input C...

Страница 5: ...status RIGHT BANK 5 2 alarm 4 15 RBSW status 3 3 12 6 16 Gnd 2 LEFT BANK 2 4 alarm 1 17 LBSW status RIGHT BANK 5 5 alarm 4 18 RBSW status 3 6 12 6 19 Gnd 3 LEFT BANK 2 7 alarm 1 20 LBSW status RIGHT B...

Страница 6: ...rm the 4 conductor cable already exists Remove the cable from the old alarm by unscrewing the wires from the terminal block Cut the end of the cable so that the wires that went into the terminals on t...

Страница 7: ...BANK 1 12 12 2 24 LBSW status RIGHT BANK 3 23 RBSW status 4 25 Gnd Table 2 CONNECTING THE OUTPUTS The Multi Station Remote Alarm activates relay contacts in response to alarm conditions These relay co...

Страница 8: ...the Alarm will make this information available to the Serial Port as an 8 bit word The data is organized such that each bit represents the status of a BANK Pressure Switch Table 5 shows the bit assig...

Страница 9: ...is limited to the following Command Code Keystroke Definition CAN Hex 18 Cntrl X Cancel ENQ Hex 05 Cntrl E Enquire STX Hex 02 Cntrl B Start of Text ETX Hex 03 Cntrl C End of Text DC4 Hex 14 Cntrl T D...

Страница 10: ...o set the unit on a flat surface With the Alarm placed so that the Input Output connectors are facing towards you unscrew the four 4 screws that hold the cover on They are retained in the cover so the...

Страница 11: ...m the Remote Alarm 2 It is best to set the unit on a flat surface With the Alarm placed so that the Input Output connectors are facing towards you unscrew the four 4 screws that hold the cover on They...

Страница 12: ...ing Option 2 4 pin connector Autoswitch check that DIP switch 5 is properly set Refer to Configuring the Remote Alarm section of the manual Outputs do not appear to be functioning 1 Check the cable to...

Страница 13: ...LECTRICAL SPECIFICATIONS Multi Station Remote Alarm 120 Volt Version 120 Volts 10 50 60 hz 6VA 220 Volt Version 220 Volts 10 50 60 hz 6VA Fuses 120 Volt Version 0 5A normal blow type 3AG 220 Volt Vers...

Страница 14: ...14 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 15: ...one other than CONTROLS CORPORATION OF AMERICA or if the equipment has been subject to abuse misuse negligence or accident CONTROLS CORPORATION OF AMERICA s sole and exclusive obligation and Buyer s s...

Страница 16: ...Number Description 1 5295310 01 001 120 VAC MULTI STATION REMOTE ALARM 1 5295311 01 001 220 VAC MULTI STATION REMOTE ALARM INCLUDES 1 8308824 120 VAC MULTI STATION REMOTE ALARM 1 8308825 220 VAC MULTI...