USER RESPONSIBILITY

This equipment will perform in conformity with the description thereof 

contained in this manual and accompanying labels and/or inserts when 

installed, operated, maintained, and repaired in accordance with the 

instructions provided.  This equipment must be checked periodically.  

Defective equipment should not be used.  Parts that are broken, missing, 

worn, distorted or contaminated, should be replaced immediately. Should 

such repair or replacement become necessary, CONCOA recommends 

that a telephone or written request for service advice be made to CONCOA 

Customer Service  in Virginia Beach, Virginia, PHONE:  1-800-225-0473, 

FAX:  1-757-422-3125, or E-MAIL: [email protected].

This equipment or any of its parts should not be altered without prior 

written approval by CONCOA.  The user of this equipment shall have the 

sole responsibility for any malfunction that results from improper use, 

faulty maintenance, damage, improper repair, or alteration by anyone 
other than CONCOA or a service facility designated by CONCOA.

CUSTOMER SERVICE

In the event of equipment failure, call CONCOA Customer Service.  Please 

be prepared to provide the model number and serial number of the 

equipment involved, in addition to some details regarding its application.

GENERAL SAFETY PRACTICES

This regulator is not for use with flammable gases.

Specific procedures for the safe use of this equipment are listed below.  

  a. The regulator relief valve protects only the regulator and is 

not intended to protect any other equipment.  Be sure the 

equipment with which it is used is also protected by relief 

device(s) if such equipment can not withstand full cylinder 

pressure.

  b. Never use the regulator for gases other than labeled.  It is 

designed to withstand 3000 psig maximum inlet pressure.

 

c.  All connections to the regulator must be clean.  Remove dirt or 

other foreign matter from the regulator and metal connecting 

parts with a clean lint free cloth.  Be sure to use a new gasket 

for each installation when a gasket is used.

!

SAFETY

Содержание 308 Series

Страница 1: ...l Certified ISO 9001 ADI 3005 D Controls Corporation of America 1501 Harpers Road Virginia Beach VA 23454 To Order Call 1 800 225 0473 or 757 422 8330 Fax 757 422 3125 www concoa com Before Installing...

Страница 2: ...2 This Page Intentionally Left Blank...

Страница 3: ...maintenance damage improper repair or alteration by anyone other than CONCOA or a service facility designated by CONCOA CUSTOMER SERVICE In the event of equipment failure call CONCOA Customer Service...

Страница 4: ...e regulators These regulators have metal diaphragms which make them ideal for general laboratory uses as well as pressure control devices for critical analytical procedures Generally these regulators...

Страница 5: ...fully and the required gas flow is ready for use f Close the cylinder valve and unplug the line cord from the supply receptacle whenever the regulator is not in use g Before making any electrical conn...

Страница 6: ...ont In case of malfunction returnRegulatorforrepairtothenearestCONCOAdesignatedrepair location as special tools tests and techniques are required CAUTION Itisrecommendedthatallservicingbedonebyaservic...

Страница 7: ...estic BLACK WIRING DIAGRAM or BROWN or GREEN YELLOW BLUE or Secondary Primary Relief Valve INLET OUTLET Thermostat Thermostat WHITE WHITE WHITE BLACK GREEN or GREEN YELLOW BLACK 115 V Domestic 115 V D...

Страница 8: ...quate heat 10 No heat Probable Cause 1 Leak across the seat 2 Loose case or damaged diaphragm 3 Damaged gauge 4 Damaged gauge 5 Damaged gauge 6 Damaged or loose connection fittings gauges orspringcase...