CLEANING AND REPLACEMENT OF THE AIR OUTLET FILTER
1. Open the air outlet grille at the back of the vacuum cleaner (Fig. 5).
2. Remove the air outlet filter. This filter can be cleaned by mechanical tapping and
cleaning with a soft brush. A much soiled filter can be washed after this step and
cleaned with a soft brush in lukewarm water without detergents. It is important to
let the wet parts dry thoroughly. A wet filter would be depleted by vacuuming! Do
not use a hair dryer for drying!
Note
: Wet cleaning can cause more wear on the filter and thereby shortening its
life.
3. Insert a clean or new air outlet filter into the vacuum cleaner and close the air
outlet grille.
TROUBLESHOOTING
Problem
Cause
Remedy
The motor is not working
The plug inserted incorrectly or
insufficiently in the wall outlet.
Check connection of the plug.
The wall outlet is not energized.
Check the presence of voltage, e.g.
with another appliance.
The motor stopped
working
Poor or too low airflow, thermal motor
protection has tripped.
Unplug the power cord.
Check
and clear the intake and exhaust
air passage, filter cleanliness, and if
necessary, replace the dust bag. Allow
the vacuum cleaner to cool down.
The front cover cannot be
closed.
Dust bag incorrectly inserted.
Check the dust bag insertion
Reduction of suction
power
Filled or clogged dust bag.
Replace the dust bag.
Filter is clogged.
Clean or replace the filter.
Clogged nozzle, tubes or hose.
Check and clear the intake and exhaust
air passage.
The vacuum cleaner is
warming up
Warming up of the vacuum cleaner during operation is normal, it is not
a malfunction.