Страница 1: ...Concept Pro VHSD 810EXT Speed Dome System User Manual Rev 2 030V ...

Страница 2: ...Contents Before installing Key features Configure fix and wire Basic speed dome operation Programming the speed dome Running selected features Specifications Installer notes 1 2 3 5 6 12 13 14 ...

Страница 3: ...be installed to prevent damage to the speed dome Any safety warnings on the product and in these instructions must be adhered to If cleaning is necessary disconnect power to the speed dome first Do not use abrasive cleaners as these will cause damage to the cover and cause poor image quality Use a damp cloth to gently clean the dome cover and dry off with a soft clean cloth Do not use any brackets...

Страница 4: ...r or an alarm input Specific parameters such as preset speed dwell time and action loop can also be specified Park function The speed dome can be configured to run a specified VST function pattern tour group or preset after a defined period of inactivity Privacy zones By defining a privacy zone sensitive scenes such as windows can be masked off so they cannot be viewed by the operator Up to 4 priv...

Страница 5: ...F OFF OFF OFF OFF OFF ON OFF OFF ON OFF OFF OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF OFF OFF OFF OFF OFF ON OFF OFF OFF 1 2 3 5 7 255 4 6 8 OFF ON OFF OFF ON ON ON Pelco D 2400 bps Pelco D 9600 bps Pelco P 4800 bps Pelco P 9600 bps Protocol Rate 1 1 1 2 3 4 5 6 7 8 DIP 2 4 8 16 32 64 128 Val ID 2 Note Dip switches 3 4 are reserved and must no...

Страница 6: ...rk through the logical steps below to determine and rectify the problem No picture Check that the PSU is correctly connected and has power If you have a test meter verify that the output of the PSU is 12V DC If the PSU is OK check the BNC crimp connection is correctly made at both the speed dome end and the DVR monitor matrix end A portable test monitor connected directly to the video output of th...

Страница 7: ...1 128 but note that preset 95 is reserved and cannot be used The preset position is cleared from memory To re programme a preset position follow the steps for programming a preset it is not necessary to delete the old preset position first Note any or all of the OSD items can be disabled in the speed dome setup menu if required PRESET LABEL If defined is displayed when a preset position is called ...

Страница 8: ...be defined MOTION SETUP setup of the pan tilt zoom operation of the speed dome park action configuration and configuration of the alarm inputs FUNCTION SETUP Allows configuration of presets VST functions patterns groups and scheduled events CAMERA SETUP Allows configuration of the operating parameters of the 10x zoom module SYSTEM SETUP Allows configuration of time date fan heater operating temper...

Страница 9: ...highlight MOTION SETUP and key NEAR PRESET LOCK ON OFF when set to ON preset programming from the keyboard is disabled PWR UP ACTION ON OFF when set to ON the last operation is resumed when power is restored after a power failure AUTO FLIP ON OFF when set to ON the dome will flip when tilt reaches 90 degrees JOG MAX SPEED the maximum speed in degrees second during manual operation JOG DIRECTION IN...

Страница 10: ...128 The preset number currently being modified If the preset number is already defined the speed dome will move to that preset position otherwise UNDEFINED is displayed under the preset number EDIT SCENE use this option to program the preset position EDIT LABEL use to edit the preset label CLR PRESET use this option to delete the current preset position CAM ADJUST Can be changed to SPECIAL which a...

Страница 11: ...ight the item to modify and key NEAR Use the joystick to change the setting and key NEAR to save or FAR to cancel Pattern setup EDIT PATTERN 1 MOVE TO START POSITION NEAR START FAR CANCEL EDIT PATTERN 1 From the pattern setup menu use the joystick to highlight EDIT PATTERNand key NEAR Position the speed dome to the desired starting point and key NEAR Move the dome to the various positions and zoom...

Страница 12: ...ules MASTER ENABLE ON OFF switches all schedule operations ON or OFF Schedule header explanation DAY Can be set to ALL for every day of the week a specific day or WKD for weekends only TIME Uses the 24 hour clock format to set the desired operation time ACT is the action to be performed and can be set to PRS preset VST PTN pattern GRP group or HOM home No is the number of the chosen action eg oper...

Страница 13: ...our content can be adjusted Highlight the item to modify and key NEAR Use the joystick to change the setting and key NEAR to save or FAR to cancel AUTO Auto exposure setup AE SETUP BACKLIGHT DAY NIGHT BRIGHTNESS IRIS SHUTTER AGC SSNR DSS BACK EXIT From the zoom camera setup menu use the joystick to highlight AUTO EXPOSURE SETUP and key NEAR BACKLIGHT ON OFF switches backlight compensation ON or OF...

Страница 14: ...er and key NEAR to insert it in the password The solid white square moves to the next cursor position Repeat until password entry is complete If a mistake is made use the joystick to select the backspace and key NEAR The cursor moves back one square Select OK to save the password or CANCEL to lose changes and key NEAR to exit Remember When CHECK PASSWORD is set to ON each time the operator attempt...

Страница 15: ...NO NO NO Once pattern tours groups and VSTfunctions have been programmed inthe speed dome setup menu they can be accessed directly from the VA KBDPRO by using the following sequences 1 To start a pattern tour key either X PATTERN or PRESET 13X ENTER Where X is a pattern tour between 1 4 2 To start a VST function keyeither X VST or PRESET 14X ENTER Where X is a VSTnumber between 1 8 3 To start a gr...

Страница 16: ... character title per preset Pattern tours Up to 4 VST function Up to 8 speed adjustable Groups Up to 8 each with up to 20 actions preset pattern tour or VST function Privacy zones Up to 4 user definable Schedules Up to 8 user definable Park function Park to specified preset pattern or scan after a defined period of inactivity 1 min 4 hours Communication Data type RS 485 Protocols Pelco D or Pelco ...