background image

IP CAMERA QUICK START GUIDE

5. Troubleshooting

Common Issues Answered

Can’t find the camera IP address using Concept Pro Lite or other software:

•  Make sure Ethernet and/or DC power cables are correctly connected to the camera.
•  Make sure the PoE switch or DC power source meets the camera power requirements.  

If using PoE, make sure the PoE switch is powered on.

•  Make sure the PC is on the same network as the camera. Ping the camera’s IP address. 

On your PC, go to Start>Programs>Accessories >Command Prompt. Type ping then the 
camera’s local IP address and press Enter. If you get the message “Request timed out,” 
PC and camera are not on the same network or camera is not connected. Camera is 
connected if you receive replies.

•  Connect the BNC test cable to the camera and the other end to a test monitor. The 

monitor display shows the camera’s IP address. A default IP address of 192.168.0.120 may 
mean that the camera cannot obtain an IP address from the router. Check the Ethernet/

power connections and router configuration.

•  Camera set for static IP mode using an incorrect IP address. By default, the camera is set 

for DHCP mode, which means it will automatically obtain an IP address from your router. 
Reset the camera to factory default settings by removing the camera dome cover and 
pressing the reset button for 5 seconds or more.

Can’t connect to the camera on a web browser using local IP address:

•  See steps above.
•  Verify the camera’s local IP address using one of the methods listed in  

“Finding the Camera IP Address.”

Can’t connect to camera on a web browser using a DDNS address:

•  Port forwarding not set up. Make sure the HTTP port (default: 80) and Control port  

(default: 30001) are forwarded on your router to the camera local IP address.

•  Multiple cameras using same port number to connect. Configure each camera to use 

different ports and port forward the new ports.

•  DNS servers not set correctly in the camera network settings

•  If DHCP is enabled on the camera and connected to an NVR, the NVR will configure the 

default settings of the camera.

Can’t connect to camera video on a web browser:

•  If using IE, make sure to install ActiveX plug-in or Adobe Flash Player.
•  If using a browser other than IE. (e.g. Google Chrome, Apple Safari, Mozilla Firefox), make 

sure the latest version of Adobe Flash Player is installed.

Video performs poorly on browser:
•  Insufficient bandwidth available for high-quality stream1. Select stream 2 under Stream. 

Stream 2 provides a lower resolution to conserve bandwidth and improve performance on 
low-bandwidth connections.

•  If using IE, click the message above the video area to use ActiveX plug-in instead of Flash 

Player. ActiveX may provide smoother video performance.

User account is locked:

•  User accounts are locked when the password has been incorrectly entered 3 Times. 

To unlock the account, login to the camera web interface as admin. Click Privilege 
Manager>User. Under User, select the locked user account and click Unlock to unlock the 
account.

Содержание CVP9328DNIR-IP2M-Z

Страница 1: ...P2M Z CVP9328DNIRLL IP2M Z CVP9328DNIR IP4M Z CVP9328DNIR IP4M G Z CVP9328DNIR IP8M Z IP External Eyeball Camera QUICK START GUIDE IP CAMERA QUICK START GUIDE QUICK START GUIDE QUICK START GUIDE Technical Documents ...

Страница 2: ... unscrew the base ring to separate the camera and middle ring from the base 2 Drill Mounting Holes Attach the included mounting template on the mounting surface and drill holes according to the template Insert included wall plugs into the holes Place the base over the holes and use the supplied fitting screws to secure the base to the surface 3 Mount the Camera Insert cables through the mounting h...

Страница 3: ...If using DC12V AC24V to power the camera ensure the power supply matches the camera power supply requirements specified and connect to the camera DC12V AC24V power input Connect the RJ45 connector to a network switch If the network switch supports Power over Ethernet PoE disconnect any DC12V AC24V power connections View the image on a monitoring device such as a BNC test monitor to confirm the pow...

Страница 4: ...rnet Explorer When prompted install the ActiveX controls for the best remote web viewing experience The default user name is admin and the default password is admin Note After first logging in to the IP camera you will be prompted to change the default password to a secure password This is highly recommended for all users to ensure proper device security Using the Concept Pro Test Monitor VLEDTM T...

Страница 5: ...cal IP address See steps above Verify the camera s local IP address using one of the methods listed in Finding the Camera IP Address Can t connect to camera on a web browser using a DDNS address Port forwarding not set up Make sure the HTTP port default 80 and Control port default 30001 are forwarded on your router to the camera local IP address Multiple cameras using same port number to connect C...

Страница 6: ...ditions Severe lighting change or flicker can cause the camera to work improperly 6 Never use the camera close to a gas or oil leak 7 Do not disassemble the camera 8 Never let the camera directly face a strong light source 9 Ensure all removable covers are replaced to protect the inner components 10 Do not install near devices which emit a strong electro magnetic field 11 Use a dry or damp cloth o...

Страница 7: ...work bandwidth usage and reduced storage space requirements compared to normal H 264 usage Note bandwidth storage savings depend upon the stream settings and CCTV monitoring environment and results may vary To enable H 265 video compression log in to the camera from a web browser Navigate to the Configuration tab then select Stream Base Stream Select H 265 under Video Encode Type and click Apply ...

Страница 8: ......

Отзывы: