TPBM024-0207
MODELS
TB45-4
Performance characteristics
Batch size lb {g}
1.0 {450}
Maximum throughput rate lb/hr {kg/hr}*
200 {91}
Bin capacity - main ingredient ft
3
{liter}
0.2 {5.7}
Bin capacity - minor ingredient ft
3
{liter}
0.2 {5.7}
Maximum number of materials
4
Number of vertical discharge valves
4
Number/(size) of major bin valves
2 - (40 mm)
Number/(size) of minor bin valves
2 - (20 mm)
Dimensions
inches {mm}
A - Height above mounting plate†
30.90 {785}
B - Width
23.63 {600}
C - Depth
25.78 {655}
D - Control height
8.25 {209.6}
E - Control width
9.25 {235.0}
F - Control depth
4.75 {120.6}
Weight
lbs {kg}
Installed
75 {34}
Shipping
125 {57}
Voltage
total amps
115V/1 phase/60 hz
1.0
230V/1 phase/50 hz
0.5
Compressed air requirements
Discharge valves
90 psi @ 0.2 ft
3
/min {6 bars
@ 0.09 liters/sec}; 1/4 in. NPT fitting
Maximum loader sizes
8 inch loaders
Number of loaders - 4
Top view
Front view
Side view
SPECIFICATION NOTES
*
Maximum throughput rates are based on 35 lb/ft3 pel-
letized material and using all standard valve sizes. Use
of reducer inserts will lower the rate shown.
†
The optional flow control valve will mount inside the
chassis in the space of the manual slide valve. Conair
recommends using the optional flow control valve when
mounting the blender on a stand, surge bin or hopper.
‡ Hopper positions three and four are supplied with
eight inch cover plates as standard.
Specifications may change without notice consult with a
Conair representative for the most current information.
7-7/8 {200}
1-25/32
diameter
{45}
5 {127}
3-3/4 {95}
7-15/32 {190}
1-7/16
{37}
1-1/4 {31}
3-15/16
{100}
5 {127}
Control
MOUNTING INTERFACE
A
B
C
F
E
D
Position 1
Position 2
‡
Position 4
‡
Position 3
Dimensions shown
in inches and
{mm}.
4
3
1
4
Mixing chamber access door -
this side of the interface.
Mounting bolt hole size (4 holes) 7/16 inch {11.0 mm}.
Predrilled 5 x 5 mounting pattern as standard.
Purchase the
optional
material drain chute
that readily installs to the
chassis opening of the
blender for
fast and
simple cleanout.
Drain chute
T r u e Bl e nd™ T B 4 5 - 4
T e c h n i c a l S p e c i f i c a t i o n s
2
2
Edition:
February
200
7
Содержание TrueBlend TB500-4
Страница 2: ......
Страница 138: ...Appendix TrueBlend 136 Edition February 2007 11 1 2 Menu overview dosing unit...
Страница 139: ...TrueBlend Appendix Edition February 2007 137 11 1 3 Menu overview conveying Optional...
Страница 140: ...Appendix TrueBlend 138 Edition February 2007 11 1 4 System settings menu...
Страница 141: ...TrueBlend Appendix Edition February 2007 139 11 1 5 Unit settings menu...
Страница 142: ...Appendix TrueBlend 140 Edition February 2007 11 1 6 Conveyor settings menu...