IT801 Web-Programmable Thermostat Manual
PROGRAMMING THE THERMOSTAT
Set Program
The IntelliTEMP DirectLink is shipped with an energy-saving schedule pre-programmed. You can customize this default
program by following the steps below if the pre-programmed schedule is not ideal for your needs.
Set Program Schedule
1.
From the main operating screen, press
MENU
.
2.
Press
SCHED
.
NOTE: Mo is displayed to indicate that Monday’s Time of Day (TOD) schedule is selected. HEAT is displayed to indicate
that the heat mode programming is selected. The first TOD period* for your configuration is displayed to indicate the TOD
period being programmed.
NOTE: To program the
COOL
schedule, press the
SYSTEM
button until
COOL
is displayed and follow steps 3 through 10.
3.
Time is flashing to indicate it is the value to be changed. Use the
or
key to make your time selection.
4.
Press
NEXT
to advance to the setpoint for the TOD period.
5.
The setpoint is flashing to indicate it is the value to be changed. Use the
or
key to make your setpoint
selection.
6.
To run the fan continuously during this TOD period, press the
FAN
key to
change the setting from AUTO to ON.
7.
Press
NEXT
to advance to the next TOD period.
8.
Repeat steps 3 through 7 for the remaining TOD periods for that day.
9.
Once all TOD periods have been programmed for the first day, repeat steps 3
through 8 for the remaining days.
10.
When complete, press
DONE
to return to the main operating screen.
*MORNING
for 4 TOD,
DAY
for 2 TOD,
OCCUPIED
for Commercial thermostat setting
Programming Tip: Rather than going through all of the weekdays to modify the Sa or Su programming, you can press
PREV
after entering the schedule programming screen to jump to the end of the week and go backward through the schedule
programming.
NOTE:
If the thermostat is configured for 2 TOD periods or the commercial setting is set to ON, there will only be two (2) TOD
periods per day to program.
A Note about
Programmable Fan:
The programmable fan feature will
run the fan continuously during any
time period it is programmed to be
on. This is the best way to keep the
air circulated and to eliminate hot
and cold spots in your building.