Manual override control in the event of power failure.
1 - Remove the cap head
screw on the top of the black
motor housing.
2 - Insert a 6mm allen key in
the drive of the motor. Turning
clockwise or counter-clockwise
will lift or lower the platform in
the event of motor failure.
1:
2:
Note:
When lift unit is manually moved to
the travel position, re
fi
t cap screw and
take to an authorised service agent for
inspection and repair. In the case of a
fl
at battery, it will need to be
recharged fully before the unit should
be operated again.