RocketPort® 485 Hardware Installation
6 of 8
Setting the DIP Switches
The RocketPort ISA card uses a DIP switch to set the base
I/O address range. The default value is 180 (hex). If you
are installing more than one RocketPort card, or if you
experience an I/O address conflict with another device, use
the DIP switches to change the I/O address.
For example, if you install two RocketPort cards and are
using the default address range:
The following table lists possible DIP switch settings. We
recommend starting with the default settings and making
changes only if the default values produce conflicts.
Notes:
1. If installing a single RocketPort ISA card, set the DIP
switches as shown in the table.
2. If installing two ISA cards, set the DIP switches on the
second card the same as the switches on the first card,
EXCEPT SWITCH 5 OFF.
3. If installing three ISA cards, follow Note 2 for the second
card, then set the DIP switches on the third card the
same as the switches on the first card, EXCEPT
SWITCH 6 OFF.
4. If installing four ISA cards, follow Notes 2 and 3 for the
second and third cards, then set the DIP switches on the
fourth card the same as on the first card, EXCEPT
SWITCHES 5 AND 6 OFF.
Specifications
The following tables illustrate RocketPort conditions and
specifications.
Sample DIP Switch Settings
1st RocketPort
180 (hex)
2nd RocketPort
(Software address can be
any unused I/O address)
First ISA Card DIP Switch Settings (see Notes)
100 - 143 hex
140 - 183 hex
180 - 1C3 hex
200 - 243 hex
240 - 283 hex
280 - 2C3 hex
300 - 343 hex
340 - 383 hex
380 - 3C3 hex
1st Card
8
7
6
5
4
3
2
1
ON
2nd Card
8
7
6
5
4
3
2
1
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
1 2 3 4 5 6 7 8
ON
Environmental Condition
Value
Air temperature:
System on
System off
0 to 40
o
C
-20 to 85
o
C
Humidity (non-condensing):
System on
System off
8% to 80%
20% to 80%
Altitude
0 to 10,000 feet
Electromagnetic Compliance
Status
Emission:
Canadian EMC requirements
CISPR-22/EN55022 Class A
FCC PART 15: Class A
Yes
Immunity:
EN50082: 801-2 ESD, 801-3 RF,
801-4 FT
Yes
UL Recognized
Yes
RocketPort 485 Card
Specification
Baud Rate:
50 to 460.8K bps
Note: Baud rate is dependent upon hardware and
operating system configuration.
Bus interface
ISA
Note: EISA files are on the Diagnostics diskette.
Control by device driver:
Data bits
Parity
Stop bits
7 or 8
Odd, Even, None
1 or 2
Current Consumption
(Values do not include
the power supplied to
external devices on
Ports 3 through 8.)
+5V
+12V
-12V
350 mA 110 mA
160 mA
Dimensions
6.25” by 4.2”
Heat output
16.6 BTU/Hr
Interfaces:
All models
With optional RS-485
feature enabled on
Ports 1 and 2
RS-232
RS-485
Interrupt (software
selectable)
None, 3, 4, 5, 9, 10, 11, 12, 15
Mean time between
failures (MTBF)
20.5 Years
Power consumption
4.87 W