The power input voltage 

of logic low is 0 to 10VDC 

and logic high is 11 to 

30VDC.  Do not apply a 

higher voltage than the 

specification; it may cause 

internal circuit damage 

or cause an incorrect DI 

action.
Digital output relay contacts are energized (open) for normal operation and 

close for fault conditions. The digital output relay contacts support up to 1A 

at 24VDC.  Do not apply voltage and current higher than the specifications. 
1.  Insert the positive and negative wires (12-24 AWG) into V+ and V-.
2.  Tighten the wire-clamp screws to prevent the wires from coming loose. 

Mounting the ES8510

You can mount the ES8510 onto a DIN rail or optionally a panel or wall.

Follow the steps below to install the ES8510 with the                                      

wall mounting plate:
1.  To remove the DIN rail clip from the ES8510,                                        

loosen the screws from the DIN rail clip.

2.  Place the wall mounting plate on the rear 

         panel of the ES8510.

3.  Use the screws to attach the wall mounting 

         plate to the ES8510.
4.     Use the hook holes at the corners of the wall 

        mounting plate to hang the ES8510 onto the wall.

Содержание ROCKETLINX ES8510

Страница 1: ...QUICK INSTALLATION GUIDE 2000515 Rev G Release Date October 2016 ROCKETLINX ES8510 ES8510 ES8510 XT ES8510 XTE ...

Страница 2: ...ents ES8510 provides a wide operating temperature ES8510 XT ES8510 XTE are NEMA TS2 certified and provide an extended operating temperature The ES8510 ES8510 XT and ES8510 XTE are referred to as the ES8510 unless there is a difference between the models See the Comtrol website for complete product specifications INSTALLATION OVERVIEW If you need more detailed installation and configuration informa...

Страница 3: ...ge ES8510 ES8510 XT 12 to 48VDC ES8510 XTE 10 to 60VDC The Power 1 2 LEDs turn red during the boot cycle and change to green when the ES8510 is ready 3 Tighten the wire clamp screws to prevent the wires from being loosened Wiring the Alarm Relay Output The ES8510 provides two digital inputs and two digital outputs dry relay output on terminal block connectors on the bottom of the unit Fault condit...

Страница 4: ...fications 1 Insert the positive and negative wires 12 24 AWG into V and V 2 Tighten the wire clamp screws to prevent the wires from coming loose Mounting the ES8510 You can mount the ES8510 onto a DIN rail or optionally a panel or wall Follow the steps below to install the ES8510 with the wall mounting plate 1 To remove the DIN rail clip from the ES8510 loosen the screws from the DIN rail clip 2 P...

Страница 5: ...ffic and link status See the LED subsection for more information Always make sure that the cables between the switches and attached devices for example switch hub or workstation are less than 100 meters 328 feet 10BASE T Category 3 4 or 5 cable 100BASE TX 1000BASE TX Category 5 or 5e cable Connecting the SFP Transceivers To ensure system reliability Comtrol recommends using Comtrol certified SFP t...

Страница 6: ...network in the ES8510 is to use a Windows host and PortVision DX see below For information about using other configuration methods refer to the appropriate RocketLinx ES8510 User Guide The following procedure uses PortVision DX to program network settings 1 Install PortVision DX on a host system with a Windows operating system If you need assistance installing PortVision DX see the appropriate Roc...

Страница 7: ...access the ES8510 without attaching an admin PC to the network You can also use out bound management if you lost the network connection to the ES8510 In band management means that you connect remotely using the ES8510 IP address through the network You can remotely connect with the ES8510 web interface or a Telnet console and the CLI The following procedure uses a web browser to configure ES8510 f...

Страница 8: ... Ring function disabled or ES8510 is on a ring but not the ring master 1 7 Green Linked to another device Amber Full Duplex Green Active traffic Not connected Collision 8 10 SFP RJ45 Green Connected Green Active connection Green Active connection Green Active connection Plugged in but not linked up Not connected COMTROL CUSTOMER SERVICE You can use one of the following methods to contact Comtrol C...

Отзывы: