QUICK INSTALLATION GUIDE

 2000641 Rev A  | Release Date  - November 2017 

Содержание ROCKET LINX MP1204-XT

Страница 1: ...QUICK INSTALLATION GUIDE 2000641 Rev A Release Date November 2017 ...

Страница 2: ...ttp downloads comtrol com which contains detailed installation and configuration information Connect the Power Terminal Block The MP1204 XT provides redundant power inputs PWR 1 2 which supports reverse polarity protection and accepts a positive or negative powersource 12V 57V However PWR1 and PWR2 must apply to the same mode Note Power should be disconnected from the power supply before connectin...

Страница 3: ... 240W PSE 2 92A 48VDC 134W 4 89A 53VDC 247W ALARM RELAY AND GROUND The alarm relay output contacts are in the middle of the DC terminal block connector as shown in the figure below The alarm relay output is Normal Open and it will be closed when detected any predefined failure such as power failures or Ethernet link failures The relay contacts have current carrying capacity of 0 5A 24 VDC ETHERNET...

Страница 4: ...and TxRx N A Connecting SFPs The SFP accepts LC connector fiber transceivers and supports both 100 1000 Mbps fiber speed connections Comtrol recommends using Comtrol approved SFP mini GBIC transceivers Note Never attempt to view optical connectors that might be emitting laser energy Do not power up the laser product without connecting the laser to the optical fiber and putting the dust cover in po...

Страница 5: ...ews in the accessory kit 2 Mount it to a wall or panel CONSOLE CONNECTION The Console port supports local management by using a terminal emulator or a computer with terminal emulation software such as puTTY The console port is located below the power connector Baud rate 115200bps Data bits 8 Stop bit 1 Parity None Flow control None Connect the RJ45 male connector to the MP1204 XT console port and ...

Страница 6: ... press the Enter key 7 Enter ip address the IP address space subnet mask and press the Enter key 8 Move the Ethernet cable to the appropriate network 9 Close the telnet session 10 Save the new IP address to the flash enter telnet and the new IP address 11 Enter the Username and Password 12 Enter copy running config startup config and press the Enter key You can now open the MP1204 XT web interface...

Страница 7: ...the Enter key 5 Enter enable and press the Enter key 6 Enter configure terminal and press the Enter key 7 Enter interface vlan 1 and press the Enter key 8 Enter ip address the IP address space subnet mask and press the Enter key 9 Enterexitandpressthe Enterkey 10 EnterexitandpresstheEnterkey 11 Enter copy running config startup config and press the Enter key You can now open the MP1204 XT web inte...

Страница 8: ...ou can use one of the following methods to contact Comtrol Contact Method Web Address or Phone Number Support http www comtrol com support Downloads http downloads comtrol com Website http www comtrol com Phone 1 763 957 6000 7 ...