Chapter 4. Commissioning the DeviceMaster UP
DeviceMaster UP PROFINET CbA User Guide
: 2000409 Rev. D
- 37
Setting a Project’s Transfer Properties
4.6. Setting a Project’s Transfer Properties
The following subsections describe how to set a project’s transfer properties. For more information, see
PROFINET CbA Communication Properties
4.6.1.
Defining Transfer Properties for the Interconnections of an Entire
Project
This procedure defines the default settings that will be applied to all new interconnections.
1.
Select
Project > Properties
.
2.
Click the
Interconnections
tab.
3.
Select the appropriate settings in the
Default setting for the new interconnections
box.
Note:
These settings will apply to all subsequently created interconnections.
4.
Select the appropriate settings in the
Transfer frequencies (cyclical)
box.
5.
Select the appropriate settings in the
Scanning frequencies (acyclical)
box.
Note:
You must set the fast value for Scanning frequencies (acyclical) to 100 ms.
6.
Click
OK
or
Accept
to confirm and save your changes.
through 5 apply to all the interconnections in the project with the corresponding
transfer mode and frequency level. These values are retained in SIMATIC iMap until they are changed again.
You can change the transfer properties of individual interconnections through the interconnection properties.
Note:
The transfer properties of a highlighted interconnection are also displayed as a tooltip.