DeviceMaster PNIO | UP User Guide
: 2000639 Rev. A
Managing the DeviceMaster - 129
Managing the DeviceMaster
Configuring Multiple DeviceMasters Network Addresses
You can configure the network addresses for multiple DeviceMasters using the
Assign IP to Multiple Devices
option.
In addition, you can also configure common settings for the DeviceMaster web
page and save the settings to a configuration file that you can load to all or
selected DeviceMasters. See
on Page 124 for more information.
The DeviceMasters must be on the same network segment for this procedure to
work. Use the following steps to configure multiple DeviceMasters.
1.
If you have not done so, install PortVision DX (
Page 24) and
Scan
the network.
2.
Shift-click the DeviceMasters
for which you want to program
network information, right-
click, and click
Advanced >
Assign IP to Multiple Devices
.
3.
Enter the starting IP address,
subnet mask, IP Gateway and
click
Proceed
.
PortVision DX displays the
programmed IP addresses in
the
Device List
pane after the
next refresh cycle.
Adding a New Device in PortVision DX
You can add a new DeviceMaster manually, if you do not want to scan the network
to locate and add new DeviceMasters, but there may be cases where you want to
use the
Add New Device
window to:
•
Configure DeviceMaster units that are not on the local network (remote) using
•
Pre-configure a DeviceMaster in PortVision DX (local) using
Remote Using the IP
Address
Use the following procedure to add a remote DeviceMaster to PortVision DX.
1.
Access the
New Device
window using one of these methods:
•
Click
Add New > Device
in the
Manage
menu.
•
Right-click a folder or a RocketLinx switch in the
Device Tree
pane
(anywhere in the pane, as long as a DeviceMaster is not highlighted and
you are in a valid folder) and click
Add New > Device
.
2.
Select the appropriate DeviceMaster in the
Device Type
drop list.
3.
Select the appropriate model in the
Device Model
drop list.
4.
Enter a friendly device name in the
Device Name
list box.
5.
Select
REMOTE
for the
Detection Type
.
6.
Optionally, enter the serial number in the
Serial Number
list box.
Содержание 99531-9
Страница 1: ...PROFINET IO User Guide ...
Страница 60: ...60 Configuring a Serial Port DeviceMaster PNIO UP User Guide 2000639 Rev A Configuring a Serial Port ...
Страница 88: ...88 IO Data Handling DeviceMaster PNIO UP User Guide 2000639 Rev A IO Data Handling ...
Страница 138: ...138 Managing the DeviceMaster DeviceMaster PNIO UP User Guide 2000639 Rev A Managing the DeviceMaster ...
Страница 148: ...148 RedBoot Procedures DeviceMaster PNIO UP User Guide 2000639 Rev A RedBoot Procedures ...