SLM-5650C / SLM-5650C-ODU Satellite Modem
Revision 1
Serial Remote Control
7–32
MN-SLM-5650C
7.5.7
Automatic Uplink Power Control (AUPC) Commands / Queries
The instruction codes that follow are valid only when the SLM-5650C Satellite Modem type has been set to
AUPC
.
Note:
Always wait three (3) seconds between consecutive remote modem command/query polls. If Local AUPC is not enabled, queries
will return the last known condition. A request for status from the remote modem will then be transmitted, ensuring that the next query will
return current status.
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments
for Command
or Response
to Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to Query
AUPC Eb/No
Target Set
Point
AET=
4 bytes
Command or Query.
AUPC Eb/No Target, where:
xx.x = AUPC Eb/No Target, 3.2 to 16.0 dB.
Example: AET=13.4
AET=
AET?
AET*
AET#
AET?
AET=xx.x
(see Description of Arguments)
AUPC
Minimum
Power Level
AMN=
5 bytes
Command or Query.
Minimum Tx Output power level, where:
s=sign ( + / – )
xx.x = Tx Output power level, +10.0 and –40.0 dBm.
Example: AMN = –13.4
AMN=
AMN?
AMN*
AMN#
AMN?
AMN=sxx.x
(see Description of Arguments)
AUPC
Maximum
Tracking
Rate
AMT=
3 bytes
Command or Query.
AUPC Maximum Tracking Rate, where:
x.x = Maximum Tracking Rate, 0.5 to 6.0 dBm/minute in increments of
.5.
Example: AMT=0.5
AMT=
AMT?
AMT*
AMT#
AMT?
AMT=x.x
(see Description of Arguments)
AUPC
Maximum
Power Level
AMX=
5 bytes
Command or Query.
Maximum Tx Output power level, where:
s=sign ( + / - )
xx.x = Tx Output power level, +10.0 and –40.0 dBm.
Example: AMX=-13.4
AMX=
AMX?
AMX*
AMX#
AMX?
AMX=sxx.x
(see Description of Arguments)
AUPC
Nominal
Power Level
ANP=
5 bytes
Command or Query.
Nominal Tx Output power level, where:
s=sign ( + / - )
xx.x = Tx Output power level, +10.0 and –40.0 dBm.
Example: ANP=-13.4
ANP=
ANP?
ANP*
ANP#
ANP?
ANP=sxx.x
(see Description of Arguments)
Содержание SLM-5650C CyberLynx
Страница 12: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Table of Contents TOC 10 BLANK PAGE ...
Страница 36: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Introduction 1 18 MN SLM 5650C BLANK PAGE ...
Страница 40: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Installation 2 4 MN SLM 5650C BLANK PAGE ...
Страница 104: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Serial Remote Control 7 10 MN SLM 5650C BLANK PAGE ...
Страница 146: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Appendix A A 12 MN SLM 5650C BLANK PAGE ...
Страница 162: ...SLM 5650C SLM 5650C ODU Satellite Modem Revision 1 Appendix B B 16 MN SLM 5650C BLANK PAGE ...
Страница 167: ......
Страница 168: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...