SLM-5650B Satellite Modem
Revision 2
Appendix C
C–18
MN-SLM-5650B
Parameter
Type
Command
(Instruction
Code and
Qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
Response to
Command
Query
(Instruction
Code and
Qualifier)
Response to
Query
DSSS-MA Max
Power Limit
TPM=
5 bytes
Command or Query.
DSSS-MA Max Output power limit, where:
s = sign ( + / - )
xx.x = Tx Output power level, +10.0 and –40.0 dBm
Example: TPM = -13.4
TPM=
TPM?
TPM*
TPM#
TPM?
TPM=sxx.x
(see Description of
Arguments)
Tx
Reed-Solomon
Interleaver Depth
TRD=
1 byte
Command or Query.
Tx RS encoding, where:
0 = Interleaver Depth 4
1 = Interleaver Depth 8
2 = Interleaver Depth 16
Depending on Modem mode, overhead type, and data rate, not all
selections will be valid.
Example: TRD = 0 (This is a ‘don’t care’ if RS is Off under TRS)
TRD =
TRD?
TRD *
TRD #
TRD?
TRD =x
(see Description of
Arguments)
Tx
Reed-Solomon
Encoding
TRS=
1 byte
Command or Query.
Tx RS encoding, where:
0 = Off
1 = On
Depending on Modem mode, not all selections will be valid.
Example: TRS = 0 (RS encoding is Off)
TRS=
TRS?
TRS*
TRS#
TRS?
TRS=x
(see Description of
Arguments)
Содержание SLM-5650B
Страница 58: ...SLM 5650B Satellite Modem Revision 2 Installation 2 8 MN SLM 5650B BLANK PAGE ...
Страница 142: ...SLM 5650B Satellite Modem Revision 2 Ethernet Based Management 6 12 MN SLM 5650B BLANK PAGE ...
Страница 280: ...SLM 5650B Satellite Modem Revision 2 TRANSEC Module HTTPS Interface 10 24 MN SLM 5650B BLANK PAGE ...
Страница 328: ...SLM 5650B Satellite Modem Revision 2 Appendix B B 16 MN SLM 5650B BLANK PAGE ...
Страница 394: ...SLM 5650B Satellite Modem Revision 2 Appendix C C 66 MN SLM 5650B BLANK PAGE ...
Страница 411: ......
Страница 412: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...