RCU101 1:1 Protection Switch 

 

 

Installation

 

 

TM055 - Rev. 2.2

 

 

 

 

Page 2-5

The ID Bits provide information to the converter that tells the converter which slot (either primary 
or backup) the converter is plugged into. The addresses are as follows: 

 

IDB4 IDB3 IDB2 IDB1 Position 

    

  0 

  1 

  0 

Backup 

    

  0 

  1 

  1 

Primary 

 

2.4.2 

Switch Fault/Status Connector (J11)

 

The RCU101 Redundancy Control Unit contains a summary Fault/Status connector that is 
available to the equipment operator for the purpose of  monitoring the summary fault status of 
both converters as well as the individual status of the converters. The pinouts of this 15-pin D 
SUB connector are as follows: 

 

J11 DB15   Description 

        1   

 

Primary Converter Summary Fault Relay Com. 

        2   

 

Primary Converter Summary Fault Relay N.C. 

        3   

 

Primary Converter Summary Fault Relay N.O. 

        9   

 

Backup Converter Summary Fault Relay Com. 

        4   

 

Backup Converter Summary Fault Relay N.C. 

        5   

 

Backup Converter Summary Fault Relay N.O. 

       10   

 

Switch Online Status Com. (B active/A inactive) 

       11   

 

Switch Online Status N.C. (Primary Online) - continuity 

       12   

 

Switch Online Status N.O. (Backup Online) - continuity 

       13   

 

Remote Primary (Active Low) 

       14   

 

Remote Backup (Active Low) 

        6   

 

Switch Summary Fault Relay Com. (Active on OK/Inactive on Fault) 

        7   

 

Switch Summary Fault Relay N.C. 

        8   

 

Switch Summary Fault Relay N.O. 

       15   

 

Ground 

The primary and backup summary fault relay contacts provide fault indications to flow through 
the switch into one common connector. In addition, the two Form-C summary fault contacts on 
the test fault connector on the rear of the RCU101 provide a Form-C closure to indicate which 
converter is presently online. Continuity of these contact closures implies online status for the 
indicated converter. 

2.4.3 

RCU101 RF and IF Rear Panel Connectors 

The following paragraphs describe the RF and IF connectors located on the rear panel of the 
RCU101. 

2.4.3.1  J3 RF Primary 

The RF Primary connector goes to the RF port of the primary converter.  This connection is 
made via the supplied semi-rigid cable with the RCU101 system.  If the primary converter is 

Содержание Radyne RCU101

Страница 1: ...ontained in this document supersedes all previously published information regarding this product This manual is subject to change without prior notice RCU101 1 1 Converter Protection Switch Installati...

Страница 2: ...Copyright 2002 Comtech EF Data All rights reserved Printed in the USA Comtech EF Data 2114 West 7th Street Tempe Arizona 85281 USA 480 333 2200 FAX 480 333 2161...

Страница 3: ...nd for the stated period following the date of shipment Upon beginning of the applicable Radyne ComStream warranty period all customer s remedies shall be governed by the terms stated or referenced in...

Страница 4: ...UNIT OR PRODUCT OR SERVICE FURNISHED OR TO BE FURNISHED AS THE CASE MAY BE WHICH IS THE SUBJECT OF CLAIM OR DISPUTE Statements made by any person including representatives of Radyne ComStream which a...

Страница 5: ...lar purpose No responsibility for any errors or omissions that may pertain to the material herein is assumed Radyne ComStream Corporation makes no commitment to update nor to keep current the informat...

Страница 6: ...h Fault Status Connector 2 5 2 4 3 RCU101 RF and IF Rear Panel Connectors 2 5 2 4 4 Interfaces Common to the Converters 2 6 2 4 5 Operator Serial I O 2 6 2 4 6 Up Downconverter Equipment RS485 Port 2...

Страница 7: ...TM054 Rev 2 2 vi...

Страница 8: ...tching of both the RF and IF signal paths Converter fault and circuit restoration is initiated from the summary fault contacts of the online converter Upon clearing of the fault in the online converte...

Страница 9: ...Description SFC4200 C Band Downconverter Page 1 2 TM054 Rev 2 2...

Страница 10: ...with the following items for proper installation 1 RCU101 1 1 Protection Switch 2 One cable set per paragraph 2 3 3 Installation and Operation Manual 2 1 1 Removal and Assembly If using a knife or cut...

Страница 11: ...Installation RCU101 1 1 Protection Switch Page 2 2 TM055 Rev 2 2...

Страница 12: ...RCU101 1 1 Protection Switch Installation TM055 Rev 2 2 Page 2 3...

Страница 13: ...2 The protection switch interface connector is a DB 15 pin connector that connects each converter with the backup switch unit This cable is not daisy chained between converters but serves as a direct...

Страница 14: ...ult Relay N O 10 Switch Online Status Com B active A inactive 11 Switch Online Status N C Primary Online continuity 12 Switch Online Status N O Backup Online continuity 13 Remote Primary Active Low 14...

Страница 15: ...ode 2 4 3 6 J8 IF Prime This BNC F connector goes to the IF connector of the primary converter This connection is made via the supplied IF cable assembly with the RCU101 2 4 3 7 J9 IF In Out This BNC...

Страница 16: ...of jumper selections is as follows Configuration JP4 1 JP4 2 JP4 3 JP4 4 JP4 5 JP4 6 JP3 JP5 JP6 JP7 JP8 RS232 OUT OUT OUT OUT IN IN OUT OUT IN OUT OUT RS422 IN IN IN IN OUT OUT OUT OUT OUT OUT IN RS...

Страница 17: ...Data and Receive Data is accomplished in the inter converter cable as the hardware interface is identical for all converters J6 DB 9 Pin Description 10 Pin AS 3048 1 GND 1 2 SRCLK 3 3 No Connect 5 4...

Страница 18: ...ed Refer to the converter manual for more details MENU for next menu ENTER for Learn Mode ENTER Automatic Learning in Process Automatic Learning Failed Automatic Learning MENU Successfully Completed R...

Страница 19: ...a Manual Command followed by an Auto Command to the converter that was deselected by the front panel switch See the applicable converter manual for more details 3 3 Switch LEDs The are two sets of id...

Страница 20: ...otection Switch Operation TM055 Rev 2 2 Page 3 3 to the converter under test This can result in unwanted operation when the converter under test is not at the same frequency or gain levels as the onli...

Страница 21: ...Operation RCU101 1 1 Protection Switch Page 3 4 TM055 Rev 2 2...

Страница 22: ...RCU101 1 1 Protection Switch Operation TM055 Rev 2 2 Page 3 5...

Страница 23: ...ll four LEDs of the graphical transfer switch display on the front panel illuminate In this case the RCU101 logic has commanded the transfer switch to a certain position This will illuminate the new p...

Страница 24: ...Maintenance RCU101 1 1 Protection Switch 4 2 TM055 Rev 2 2...

Страница 25: ...TM055 Rev 2 2 Page 5 1...

Страница 26: ...5 F QTY 1 Summary Status DB15 F QTY 1 Switch RF Specifications Switched RF Ports Bandwidth DC 18 GHz Insertion Loss 0 4 dB C band 0 5 dB Ku band Impedance 50 Ohms VSWR 1 5 1 Max Isolation 70 dB min C...

Страница 27: ...RCU101 1 1 Protection Switch Serial Protocol TM055 Rev 2 2 A 2...

Страница 28: ...TM055 Rev 2 2 B 1 Appendix B RCU101 Block Diagram Configuration Drawings and Schematics...

Страница 29: ...TM055 Rev 2 2 B 2 Figure B 1 Functional Block Diagram...

Страница 30: ...TM055 Rev 2 2 B 3 Figure B 2 Top Level Assembly...

Страница 31: ...TM055 Rev 2 2 B 4 Figure B 3 AS 3265 Front Panel Assembly...

Страница 32: ...TM055 Rev 2 2 B 5 Figure B 4 AS 3527 Switch Assembly...

Страница 33: ...TM055 Rev 2 2 B 6 Figure B 5 AS 3527 Switch Assembly...

Страница 34: ...TM055 Rev 2 2 B 7 Figure B 6 CA 4014 Cable Assembly...

Отзывы: