RCU101 1:1 Protection Switch
Installation
TM055 - Rev. 2.2
Page 2-5
The ID Bits provide information to the converter that tells the converter which slot (either primary
or backup) the converter is plugged into. The addresses are as follows:
IDB4 IDB3 IDB2 IDB1 Position
1
0
1
0
Backup
1
0
1
1
Primary
2.4.2
Switch Fault/Status Connector (J11)
The RCU101 Redundancy Control Unit contains a summary Fault/Status connector that is
available to the equipment operator for the purpose of monitoring the summary fault status of
both converters as well as the individual status of the converters. The pinouts of this 15-pin D
SUB connector are as follows:
J11 DB15 Description
1
Primary Converter Summary Fault Relay Com.
2
Primary Converter Summary Fault Relay N.C.
3
Primary Converter Summary Fault Relay N.O.
9
Backup Converter Summary Fault Relay Com.
4
Backup Converter Summary Fault Relay N.C.
5
Backup Converter Summary Fault Relay N.O.
10
Switch Online Status Com. (B active/A inactive)
11
Switch Online Status N.C. (Primary Online) - continuity
12
Switch Online Status N.O. (Backup Online) - continuity
13
Remote Primary (Active Low)
14
Remote Backup (Active Low)
6
Switch Summary Fault Relay Com. (Active on OK/Inactive on Fault)
7
Switch Summary Fault Relay N.C.
8
Switch Summary Fault Relay N.O.
15
Ground
The primary and backup summary fault relay contacts provide fault indications to flow through
the switch into one common connector. In addition, the two Form-C summary fault contacts on
the test fault connector on the rear of the RCU101 provide a Form-C closure to indicate which
converter is presently online. Continuity of these contact closures implies online status for the
indicated converter.
2.4.3
RCU101 RF and IF Rear Panel Connectors
The following paragraphs describe the RF and IF connectors located on the rear panel of the
RCU101.
2.4.3.1 J3 RF Primary
The RF Primary connector goes to the RF port of the primary converter. This connection is
made via the supplied semi-rigid cable with the RCU101 system. If the primary converter is
Содержание Radyne RCU101
Страница 7: ...TM054 Rev 2 2 vi...
Страница 9: ...Description SFC4200 C Band Downconverter Page 1 2 TM054 Rev 2 2...
Страница 11: ...Installation RCU101 1 1 Protection Switch Page 2 2 TM055 Rev 2 2...
Страница 12: ...RCU101 1 1 Protection Switch Installation TM055 Rev 2 2 Page 2 3...
Страница 21: ...Operation RCU101 1 1 Protection Switch Page 3 4 TM055 Rev 2 2...
Страница 22: ...RCU101 1 1 Protection Switch Operation TM055 Rev 2 2 Page 3 5...
Страница 24: ...Maintenance RCU101 1 1 Protection Switch 4 2 TM055 Rev 2 2...
Страница 25: ...TM055 Rev 2 2 Page 5 1...
Страница 27: ...RCU101 1 1 Protection Switch Serial Protocol TM055 Rev 2 2 A 2...
Страница 28: ...TM055 Rev 2 2 B 1 Appendix B RCU101 Block Diagram Configuration Drawings and Schematics...
Страница 29: ...TM055 Rev 2 2 B 2 Figure B 1 Functional Block Diagram...
Страница 30: ...TM055 Rev 2 2 B 3 Figure B 2 Top Level Assembly...
Страница 31: ...TM055 Rev 2 2 B 4 Figure B 3 AS 3265 Front Panel Assembly...
Страница 32: ...TM055 Rev 2 2 B 5 Figure B 4 AS 3527 Switch Assembly...
Страница 33: ...TM055 Rev 2 2 B 6 Figure B 5 AS 3527 Switch Assembly...
Страница 34: ...TM055 Rev 2 2 B 7 Figure B 6 CA 4014 Cable Assembly...