![Comtech EF Data KST-2000L Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/comtech-ef-data/kst-2000l/kst-2000l_installation-and-operation-manual_2648543050.webp)
Satellite Terminal System
Revision 2
Fault Indication and Isolation
MN/KST2000L.IOM
5.2
Fault Isolation
System faults are reported on the fault log screen in the Windows™ based remote M&C
software. (Alternatively, they may be viewed in the terminal mode as shown in
Chapter 7). Chapter 7 lists the KST-2000L faults and their indication in the LEDs and re-
lays. In some cases, items listed in Chapter 7 give no LED or relay indication when they
occur because they are not equipment faults but are useful for troubleshooting problems.
5.3
Stored
Faults
Each of the major modules within the KST-2000L (up converter, down converter, HPA,
LNB, and Reference), together with the AGC function and the Common Equipment, re-
port their individual fault status to the main M&C. Each time there is a change in the fault
status, that status is stored in a non-volatile memory on the main M&C. Note that each
event corresponds to a change in status. Therefore, when a fault occurs, that constitutes
one status change, and when that fault clears, another event occurs. The M&C can store
up to ten fault status conditions.
After ten fault status changes are logged, no further logging can take place until the Clear
Stored Faults (<add/CLSF) command is issued. Refer to Appendix B, Table B-7 for the
fault commands to access the fault status of each function. When the fault status is que-
ried, such as <add/HS_, the response returned will indicate how many stored faults are
actually stored. To retrieve the individual fault status, issue the appropriate stored fault
command with the corresponding stored fault number, such as <add/HSF_2. That particu-
lar fault condition will be returned. Note that the stored fault numbers (locations) are
0 through 9 inclusive.
It is good maintenance practice to query the stored faults and record them in a logbook or
other permanent record and then issue the clear stored fault command, <add/CLSF_.
There is no time stamp associated with these stored faults. Noting them in a logbook is
the only way to establish an approximate time reference,.
5–2
Содержание KST-2000L
Страница 2: ......
Страница 14: ...Preface KST 2000L Satellite Terminal System xii Rev 2...
Страница 20: ...Satellite Terminal System Revision 2 Introduction MN KST2000L IOM 1 6 This page is intentionally left blank...
Страница 61: ...Satellite Terminal System Revision 2 Equipment Mounting MN KST2000L IOM Figure 6 6 Installing the SSPA 6 9...
Страница 82: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...