Ku-Band Satellite Transceiver
Revision 9
Terminal Mode Commands
MN/KST2000AB.IOM
B–9
System
Maintenance
Status
Command
Response
<add/MS_’cr’
>add/MS_’cr’
UCT_nn’cr’
HPT_nn’cr’
DCT_nn’cr’
MCT_nn’cr’
PRF_nn’cr’
FTD_xxx’cr’
HV_xxx’cr’’lf’]
Where:
nn = UC Temperature in
°
C
nn = HPA Temperature in
°
C
nn = DC Temperature in
°
C
nn = M&C Temperature in
°
C
nn = Comtech EF Data HPA corrected RF
output
power
N/A = OEM SSPA
N/A = OEM TWTA
xxx = (OK/DLY or N/A) OEM TWTA only,
Heater
timer
complete
xxx = ON/OFF or N/A OEM TWTA only,
high
voltage
status
Up Converter
Current Faults
Command
Response
<add/US_’cr’
>add/US_’cr’
RF_xxx’cr’
UC_xxx’cr’
SSYN_xxx’cr’
KSYN_xxx’cr’
LSSYN_xxx’cr’
LKSYN_xxx’cr’
PROG_xxx’cr’
SFLT_#’cr’’lf’]
RF Output (ON/OFF) Actual Status
Up Converter Module (OK/FLT)
S-Band Synthesizer Lock Detect (OK/FLT)
Ku-Band Synthesizer Lock Detect (OK/FLT)
Latched S-Band Synthesizer Lock Detect (OK/FLT)
Latched Ku-Band Synthesizer Lock Detect (OK/FLT)
Inter-processor Communications (OK/FLT)
Number of stored faults (# = 1 to 10)
HP Current Faults
2 and 4 Watt
SSPAs
Current Faults
(Comtech EF
Data)
Command
Response
<add/HS_’cr’
>add/HS_’cr’
RF_xxx’cr’
HPA_xxx’cr’
BV1_xxx’cr’
+9.75V_xxx’cr’
-5V_xxx’cr’
PROG_xxx’cr’
SFLT_#’cr’’lf’]
RF Output (ON/OFF) Actual Status
HPA Converter Module (OK/FLT)
Bias Voltage #1 (OK/FLT)
+9.75 V Power Supply (OK/FLT)
–5 Volt Power Supply (OK/FLT)
Inter-processor Communications (OK/FLT)
Number of stored faults (# = 1 to 10)
HP Current Faults
8 Watt SSPAs
Current Faults
(Comtech EF
Data)
Command
Response
<add/HS_’cr’
>add/HS_’cr’
RF_xxx’cr’
HPA_xxx’cr’
BV1_xxx’cr’
BV2_xxx’cr’
BV3_xxx’cr’
+9.75V_xxx’cr’
-5V_xxx’cr’
PROG_xxx’cr’
SFLT_#’cr’’lf’]
RF Output (ON/OFF) Actual Status
HPA Converter Module (OK/FLT)
Bias Voltage #1 (OK/FLT)
Bias Voltage #2 (OK/FLT)
Bias Voltage #3 (OK/FLT)
+9.75 V Power Supply (OK/FLT)
–5 Volt Power Supply (OK/FLT)
Inter-processor Communications (OK/FLT)
Number of stored faults (# = 1 to 10)
HP Current
Faults
16 Watt SSPAs
Current Faults
(Comtech EF
Data)
Command
Response
<add/HS_’cr’
>add/HS_’cr’
RF_xxx’cr’
HPA_xxx’cr’
BV1_xxx’cr’
BV2_xxx’cr’
BV3_xxx’cr’
BV4_xxx’cr’
BV5_xxx’cr’
+9.75V_xxx’cr’
-5V_xxx’cr’
PROG_xxx’cr’
SFLT_#’cr’’lf’]
RF Output (ON/OFF) Actual Status
HPA Converter Module (OK/FLT)
Bias Voltage #1 (OK/FLT)
Bias Voltage #2 (OK/FLT)
Bias Voltage #3 (OK/FLT)
Bias Voltage #4 (OK/FLT)
Bias Voltage #5 (OK/FLT)
+9.75 V Power Supply (OK/FLT)
–5 Volt Power Supply (OK/FLT)
Inter-processor Communications (OK/FLT)
Number of stored faults (# = 1 to 10)
Содержание KST-2000A
Страница 2: ......
Страница 28: ...Ku Band Satellite Transceiver Revision 9 Introduction MN KST2000AB IOM 1 14 NOTES ...
Страница 88: ...Ku Band Satellite Transceiver Revision 9 Operation MN KST2000AB IOM 5 4 Figure 5 3 Principle Menu Trees ...
Страница 102: ...Ku Band Satellite Transceiver Revision 9 Operation MN KST2000AB IOM 5 18 NOTES ...
Страница 152: ...Ku Band Satellite Transceiver Revision 9 Redundant Equipment Mounting MN KST2000AB IOM D 12 NOTES ...
Страница 180: ...Ku Band Satellite Transceiver Revision 9 Glossary MN KST2000AB IOM g 4 NOTES ...