4.2.1.2.2
DC Operation – Apply Power
Figure 4-11. Apply DC Power to the Unit
Do these steps to apply DC power to the unit (
):
1.
Connect the user-supplied ‘-48’ (+) and ‘GND’ (–) DC power leads to their
respective terminals.
Number 18 AWG minimum wires are recommended.
2.
Connect the user-supplied DC power leads to the user power source.
3.
Energize the power source.
4.
Switch the unit ON.
4.2.2
Unit Ground Connection
Figure 4-12. Unit Ground Connection
CAUTION
PROPER GROUNDING PROTECTION IS REQUIRED.
You must connect the
equipment to the protective earth connection at all times. Use this
ground stud during installation, configuration, and operation.
The AC power interface provides the safety ground.
As shown in
and
Item 10
): Use this #10-32 stud, located
at the right side of the rear panel, for connecting a common chassis ground
among equipment.
Содержание DT-4500 Series
Страница 48: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Specifications Revision 2 2 12 Notes...
Страница 92: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Firmware Update Revision 2 5 16 Notes...
Страница 120: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Front Panel Operation Revision 2 6 28 Notes...
Страница 146: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Ethernet Interface Operation Revision 2 7 26 Notes...
Страница 180: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Serial Interface Operation Revision 2 8 34 Notes...
Страница 204: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Appendix B Revision 2 B 8 Notes...
Страница 205: ......
Страница 206: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...