DT-4500 Series C- and Ku-Band Down Converters
MN/DT4500.IOM
Front and Rear Panel Connectors
Revision 2
4–9
and
: The unit rear panel features a fuse holder
that is press-fit into the body of the IEC power module.
WARNING!
DISCONNECT THE POWER SUPPLY BEFORE PROCEEDING!
CAUTION
FOR CONTINUED OPERATOR SAFETY, ALWAYS REPLACE THE FUSES
WITH THE CORRECT TYPE AND RATING.
Do these steps to replace the AC fuses (
):
1.
Unseat the fuse holder from the IEC power module.
a.
Use the slot to pry the fuse holder outward from the IEC power
supply module.
b.
Pull the holder straight out, and then swing the holder away from the
module.
2.
Remove and replace the fuses as needed.
•
Use T2.00A 20mm fuses for AC operation.
3.
Re-seat the fuse holder in the IEC power module.
4.2.1.1.2
AC Operation – Apply AC Power
Figure 4-9. Apply AC Power to the Unit
Do these steps to apply AC power to the unit (
1.
Plug the provided AC power cord female end into the unit.
2.
Plug the AC power cord male end into the user-supplied power source.
3.
Switch the unit ON.
Содержание DT-4500 Series
Страница 48: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Specifications Revision 2 2 12 Notes...
Страница 92: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Firmware Update Revision 2 5 16 Notes...
Страница 120: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Front Panel Operation Revision 2 6 28 Notes...
Страница 146: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Ethernet Interface Operation Revision 2 7 26 Notes...
Страница 180: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Serial Interface Operation Revision 2 8 34 Notes...
Страница 204: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Appendix B Revision 2 B 8 Notes...
Страница 205: ......
Страница 206: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...