8.7.2.15
VFD (VFD Brightness)
Use VFD to set or return the front panel brightness from 0% to 100% in 25%
steps. The default VFD brightness is 100.
Description
Details
Set VFD:
<DEV/VFD_xxx{cr} where:
xx = 000 to 100 (in 025 steps)
Confirmation:
>DEV/VFD_xxx{cr}{lf}]
Return VFD:
<DEV/LCD_{cr}
Confirmation:
>DEV/VFD_xxx{cr}{lf}]
8.7.2.16
SRO (Set Reference Oscillator Tuning)
Use SRO to set or return the reference oscillator tuning. The default value is 087.
Description
Details
Set Oscillator:
<DEV/SRO_xxx{cr} where:
xxx = 0 to 255
Confirmation:
>DEV/SRO_xxx{cr}{lf}]
Return Tuning:
<DEV/SRO_{cr}
Confirmation:
>DEV/SRO_xxx{cr}{lf}]
8.7.2.17
SSA (Converter Slope Adjustment)
Use SSA to set or return the slope adjustment value. The default value is 0.3.
Description
Details
Set Slope Adjust:
<DEV/SSA_xxx{cr} where:
xxx = 0.0 to 1.0
Confirmation:
>DEV/SSA_xxx{cr}{lf}]
Return Slope Adjust:
<DEV/SSA_{cr}
Confirmation:
>DEV/SSA_xxx{cr}{lf}]
Содержание DT-4500 Series
Страница 48: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Specifications Revision 2 2 12 Notes...
Страница 92: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Firmware Update Revision 2 5 16 Notes...
Страница 120: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Front Panel Operation Revision 2 6 28 Notes...
Страница 146: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Ethernet Interface Operation Revision 2 7 26 Notes...
Страница 180: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Serial Interface Operation Revision 2 8 34 Notes...
Страница 204: ...DT 4500 Series C and Ku Band Down Converters MN DT4500 IOM Appendix B Revision 2 B 8 Notes...
Страница 205: ......
Страница 206: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX...