Connector Pinouts
3–8
MN-CRS-280/280L
3.3.2.3 Power / Ground Connections
For continued operator safety, always replace fuses with the correct type and
rating.
3.3.2.3.1 Alternating Current (AC) Power Connectors
Two AC power supplies – one primary, one backup – are provided. For each, a
standard, detachable, non-locking 3-prong power cord (IEC plug) supplies the
Alternating Current (AC) power to the CRS-280L. Observe the following:
3.3.2.3.2 Direct Current (DC) Power Connectors (optional)
Two DC power supplies – one primary, one backup – are optionally
available. For each, a standard, 3-screw terminal block with fuse
holder supplies the Direct Current (DC) power to the CRS-280L.
Observe the following:
Standard AC Power Specifications
Input Power
25W typical
Input Voltage
100 - 240 volts AC, +6%/-10% - autosensing
(total absolute max. range is 90-264 volts AC)
Connector Type
IEC
Fuse Protection
1.0A Slow-blow (115 volt AC operation)
2.0A Slow-blow (230 volt AC operation)
Line and neutral fusing
20 mm type fuses
Optional DC Power Specifications
Input Power
25W maximum
Input Voltage
36 to 72 VDC; 6.25 amps
Connector Type
Terminal Block
Fuse Protection
6.25A Slow-blow
Содержание CRS-280
Страница 28: ...CRS 280 280L IF Switch for 1 N Redundancy Revision Introduction 1 14 MN CRS 280 280L Notes ...
Страница 40: ...CRS 280 280L IF Switch for 1 N Redundancy Revision Connector Pinouts 3 10 MN CRS 280 280L BLANK PAGE ...
Страница 68: ...CRS 280 280L IF Switch for 1 N Redundancy Revision Appendix B B 8 MN CRS 280 280L BLANK PAGE ...
Страница 69: ......
Страница 70: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...