CRS-180 70/140 MHz IF 1:1 Redundancy Switch
MN/CRS180.IOM
Switch Connectors and Pinouts
Revision 11
3–3
3.1.1.5 Type ‘SMA’ (Subminiature Version ‘A’)
Type ‘SMA’ connectors feature a Threaded Coupling design similar to
Type ‘TNC’, Type ‘N’, and Type ‘F’ connectors.
3.1.2 D-Subminiature Cable Connections
Type ‘D’ Connection Type
Example
Chassis Receptacles:
(TOP) Female
(BOTTOM) Male
Type ‘D’ Cable With Jack Screws
(Female Shown)
Figure 3-2. D-Subminiature Connector Examples
D-Subminiature connectors are also called Type ‘D’ or ‘D-Sub’ connectors. The connector pair
features multiple rows of pins (male side) coupled to mating sockets (female side). The cable
plug and chassis receptacle each feature a D-shaped profile that interlock to ensure proper pin
orientation and connector seating.
Either chassis receptacle gender features two jack nuts for secure assembly of the cable plug to
the chassis receptacle.
Whether its gender is male or female, the cable plug features two jack screws for secure
connection to the jack nuts provided on the mating chassis receptacle. The jack screws may be
hand tightened or tightened with a standard flat-blade screwdriver.
Connection Instructions: Orient the plug to the receptacle in the proper position. Press firmly
into place. Use the jack screws to secure the plug to the receptacle jack nuts. Do not over-
tighten.
About connector pinout tables: Figure 3-2 identifies the Pin 1 location for either gender
connector. Unless noted otherwise, the connector pinout tables provided in this manual
arrange/order information (i.e., the Pin # column/row) based on this orientation.
3.1.3 RJ-45, RJ-48 Cable Connections
The plug for an RJ-45 or RJ-48 cable features a flexible tab. The RJ-45
or RJ-48 jack features a mating slot. This design configuration assures
proper installation and pin orientation.
Содержание CRS-180
Страница 10: ...CRS 180 70 140 MHz IF 1 1 Redundancy Switch MN CRS180 IOM Table of Contents Revision 11 x BLANK PAGE ...
Страница 18: ...CRS 180 70 140 MHz IF 1 1 Redundancy Switch MN CRS180 IOM Preface Revision 11 xviii Notes ...
Страница 46: ...CRS 180 70 140 MHz IF 1 1 Redundancy Switch MN CRS180 IOM Modem and Switch Configuration Revision 11 4 6 Notes ...
Страница 48: ...CRS 180 70 140 MHz IF 1 1 Redundancy Switch MN CRS180 IOM Modem and Switch Configuration Revision 11 4 8 Notes ...
Страница 82: ...CRS 180 70 140 MHz IF 1 1 Redundancy Switch MN CRS180 IOM Cables and Connections Revision 11 5 24 Notes ...
Страница 90: ...CRS 180 70 140 MHz IF 1 1 Redundancy Switch MN CRS180 IOM Cables and Connections Revision 11 5 32 Notes ...
Страница 110: ...CRS 180 70 140 MHz IF 1 1 Redundancy Switch MN CRS180 IOM Cables and Connections Revision 11 5 52 Notes ...
Страница 133: ......
Страница 134: ...2114 WEST 7TH STREET TEMPE ARIZONA 85281 USA 480 333 2200 PHONE 480 333 2161 FAX ...