CiM Quick Start Guide
Rev. 1
Operation
CD/CIMQSTART.IOM
9
1.8.2 C
ONFIGURATION
1.8.2.1 DES C
ONFIGURATION
Step Description
1
From the
Ma
i
n Menu
select
Adm
i
n
i
strat
i
on
sub-menu
2
From the
Adm
i
n
i
strat
i
on Menu
select the
Feature Conf
i
gurat
i
on
sub-menu
3
Enable Transm
i
t DES Encrypt
i
on
by pressing
T
4
Enable Rece
i
ve DES Dencrypt
i
on
by pressing
R
5
From the
Adm
i
n
i
strat
i
on Menu
select the
DES Conf
i
gurat
i
on
sub-menu
6
Set
Transm
i
t Key 1
to
ABCDEF0123456789
3
7
Set
Transm
i
t Key 2
to
FEDCBA0123456789
4
8
Set
Rece
i
ve
Key 1
to
0123456789ABCDEF
9
Set
Rece
i
ve Key 2
to
FEDCBA9876543210
10
From
Ma
i
n Menu
select
Route Table
sub-menu
11
Select
QOS/DES
sub-menu
12
Select first route by pressing
1
13
Press
Enter
for
M
i
n
i
mum
and
Max
i
mum Bandw
i
dth
14
Set
DES Key
to
1
(i.e. Key 2 – ABCDEF0123456789 will be used to encrypt all
datagrams on this route)
1.8.2.2 S
AVE
C
ONFIGURATION
Save parameters to permanent storage.
3
Customer may select another 16 hex digit key. This key must match the receive Key 1 on the other CiM.