Computime GES2181 Скачать руководство пользователя страница 3

PRODUCT

 

OVERVIEW

 

The

 

GES2181

 

Energy

 

Saving

 

Thermostat

 

can

 

connect

 

to

 

3

 

Heat

 

/

 

2

 

Cool

 

conventional

 

Heat

 

Pump

 

HVAC

 

systems.

 

The

 

thermostat’s

 

smart

 

ZigBee™

 

technology

 

enables

 

it

 

to

 

communicate

 

with

 

your

 

utility

 

company

 

so

 

you

 

can

 

receive

 

messages

 

about

 

energy

 

saving

 

events

 

and

 

price

 

reductions.

 

In

 

addition,

 

the

 

easy

to

use

 

interface

 

makes

 

it

 

simple

 

to

 

control

 

your

 

energy

 

consumption.

 

 

SAFETY

 

INSTRUCTIONS

 

Purpose

 

and

 

correct

 

use:

 

 

Read

 

these

 

instructions

 

carefully

 

and

 

keep

 

in

 

a

 

safe

 

place

 

for

 

future

 

reference.

 

 

Only

 

an

 

authorized,

 

qualified

 

installer

 

should

 

install

 

this

 

unit.

 

All

 

manual

 

/

 

safety

 

instructions

 

and

 

electricity

 

supplier’s

 

regulations

 

must

 

be

 

adhered

 

to.

 

 

Only

 

connect

 

this

 

unit

 

to

 

a

 

24

volt

 

A/C

 

power

 

source.

 

 

Do

 

not

 

install

 

this

 

unit

 

at

 

an

 

altitude

 

of

 

over

 

2000

 

meters.

 

 

This

 

standalone

 

mounted

 

electronic

 

unit

 

serves

 

as

 

a

 

temperature

 

control

 

system

 

only

 

in

 

dry,

 

closed

 

living

 

and

 

office

 

spaces.

 

Do

 

not

 

place

 

the

 

unit

 

in

 

a

 

bathroom

 

or

 

area

 

of

 

excessive

 

moisture.

 

Do

 

not

 

allow

 

the

 

unit

 

to

 

get

 

wet.

 

 

Place

 

the

 

unit

 

in

 

an

 

easy

to

reach

 

position

 

where

 

you

 

can

 

comfortably

 

reach

 

the

 

buttons

 

and

 

view

 

the

 

screen.

 

 

Do

 

not

 

expose

 

the

 

unit

 

to:

 

temperatures

 

below

 

5

°

C

 

or

 

above

 

40

°

C;

 

humidity

 

above

 

80%

 

or

 

pollution

 

above

 

level

 

2.

 

 

Do

 

not

 

expose

 

the

 

unit

 

to

 

voltage

 

fluctuations

 

of

 

more

 

than

 

+/

‐ 

10%.

 

 

Clean

 

the

 

unit

 

with

 

a

 

dry,

 

soft

 

cloth.

 

Do

 

not

 

use

 

solvents

 

or

 

aggressive

 

cleaning

 

agents.

 

The

 

manufacturer

 

accepts

 

no

 

responsibility

 

for

 

damage

 

caused

 

by

 

non

observance

 

of

 

these

 

instructions.

 

Environmental

 

Protection

 

Unwanted

 

electrical

 

appliances

 

can

 

be

 

recycled

 

and

 

should

 

not

 

be

 

discarded

 

along

 

with

 

regular

 

household

 

waste.

 

Please

 

help

 

to

 

support

 

the

 

conservation

 

of

 

resources

 

and

 

protect

 

the

 

environment

 

by

 

returning

 

this

 

appliance

 

to

 

your

 

nearest

 

collection

 

centre

 

(if

 

available).

 

 

INSTALLATION

 

Please

 

refer

 

to

 

Appendix

 

for

 

installation

 

guide.

 

 

HOME

 

SCREEN

 

The

 

Home

 

screen

 

is

 

the

 

main

 

display

 

screen.

 

If

 

you

 

do

 

not

 

press

 

any

 

buttons

 

for

 

30

 

seconds,

 

the

 

thermostat

 

will

 

return

 

to

 

the

 

Home

 

screen.

  

3

 

 

 

Comment [Kairy1]: 

Added

 

below

Содержание GES2181

Страница 1: ...Energy Saving Thermostat Insert product picture Instruction Manual Model no GES2181 1...

Страница 2: ...2 CONTENTS...

Страница 3: ...not place the unit in a bathroom or area of excessive moisture Do not allow the unit to get wet Place the unit in an easy to reach position where you can comfortably reach the buttons and view the sc...

Страница 4: ...of the following options Heat Cool or Off Conventional HAVC Heat Emer Emergency Heating Cool or Off Heat pump HVAC 3 Press MENU to confirm your selection and return to the Home screen Note Make sure...

Страница 5: ...u Viewing events and me In the Override menu you can choose to accept or reject events and messages and set the thermostat to Vacation to override the programmed settings T 1 Select and enter the Over...

Страница 6: ...erature settings for any day of the week 1 Select and enter the Program menu and the screen opposite appears 2 Use UP or DOWN to scroll through the settings and press SYS or FAN to change a setting 3...

Страница 7: ...and return to Time Changes the time Date Changes the date Get Network Time If you select and confirm Yes a signal will be sen will be updated on your thermo t out to search for the network time and th...

Страница 8: ...he Ne Joined screen opposite 2 Press SELECT to disconnect and the message Are appears 3 Press and hold MENU and INFO simultaneously to co press MENU to exit and return to the pre Note The right LED li...

Страница 9: ...i e 8am DURATION The event will last for this duration i e 2 hours Your current energy usage is priced at Level 1 which is currently 2 2 per kilowatt hour A Price A Message Your utility company will s...

Страница 10: ...ettings progra med in the thermostat in response to different energy price level Below is a table of for the Price ffset vel LED Indicator Offset in F When ok in the top lor and the other is tri color...

Страница 11: ...ed by UL cUL CSA Disconnection means Type 1B Pollution Degree 2 Warning Changes or modifications to this unit not expressly approved by the esponsible for compliance could void the user s authority to...

Страница 12: ...12 lse voltage 330V allation please refer to the install Warning Do not connect any of the termi ply Rated Impu For inst ation and wiring diagram under Appendix nals to 110V 220V AC sup...

Страница 13: ...common for control circuit and thermostat power input Fan 1st stage cooling 1st stage compressor 2nd stage cooling 2nd stage compressor 1st stage heating Auxiliary heating 2nd stage heating Emergency...

Страница 14: ...14 iring diagram for Heat pump system W Aux heating Emergency...

Страница 15: ...15 system Wiring diagram for conventional Heat Cool 2010 Computime Limited...

Отзывы: