background image

1. GENERAL DESCRIPTION

The 

COMPUTHERM 

Q2RF 

plug was developed for the 

COMPUTHERM

 

Q3RF

Q5RF

Q7RF

 and 

Q8RF 

thermostats to increase their wire-

less range. The original range of 

Q3RF

Q5RF

Q7RF

 and 

Q8RF

 ther-

mostats  is  50  m  in  open  area,  which  can  be  significantly  shortened 

by  the  structure  of  the  building.  To  be  able  to  use  the 

Q3RF

Q5RF

Q7RF

 and 

Q8RF

 thermostats in larger buildings too, it is advised to 

use  a  wireless  signal  repeater.  This  can  be  achieved  by  using  the 

 

COMPUTHERM 

Q2RF

 wireless repeater: it receives the signals of the 

wireless thermostats and retransmits the signal to the receiver unit, thus 

making the range larger. The range of the signal sent by the signal repeat

-

er is approx. 100 m. The 

Q2RF 

plug should be connected to the mains 

voltage (230 V, 50 Hz), meanwhile on the output of the 

Q2RF 

plug the 230 

V, 50 Hz mains voltage also appears. The maximum load of the plug is be 

16 A (4 A inductive).

2. PUTTING THE WIRELESS REPEATER  

    INTO OPERATION

When  choosing  the  location  of  the  signal  repeater  unit  you  should  re

-

member that bulky metal objects (e.g. a boiler, buffer tank, etc.) and metal 

building structures may have an adverse effect on propagation of radio 

waves. If it is possible, in order to ensure trouble-free RF connection, we 

recommend that you install the receiving unit at a height of 1.5 to 2 m and 

at a distance of 1 to 2 m from the boiler or other bulky metal construc

-

tions. It is advisable to install the 

COMPUTHERM

 

Q2RF

 signal repeater in 

a place protected from moisture, dust, chemicals and heat. 

WARNING! Modifying the socket can cause electric shock or prod-

uct failure.

Connect the 

COMPUTHERM

 

Q2RF

 wireless repeater plug to the mains 

voltage,  approximately  half  way  between  the 

Q3RF

Q5RF

Q7RF

 and 

Q8RF

 thermostat and Its receiver unit. After a couple of seconds the 

LEDs on the front panel of the plug flash once, after which the plug is 

ready for operation. Without tuning the device together with the thermo

-

stat or its receiver unit, it receives the signals from all 

Q3RF

Q5RF

Q7RF

 

and 

Q8RF

 thermostats in its range, after which it transmits the signal to 

the receiver unit using the same security code. The receiving and the the 

sending of the signals are shown by the followings: red LED blinks two 

times,  then  both  LEDs  blink  one  time  and  finally  the  green  LED  blinks 

2 times. It causes absolutely no problems if there are more thermostats 

working in the range of the wireless repeater: as the security codes are 

kept for the repeated signals, an incorrect switch is not possible. 

3. FAST CHECK OF THE OPERATION OF 

THE WIRELESS REPEATER

By  pressing  the  „

TEST

”  button,  the  verification  of  the  operation  of  the 

Q2RF 

plug is easy, fast and can be done within one room by following the 

steps below:
1. Unplug the 

Q2RF

 device, in case it was plugged in before, and wait ap-

proximately 1 minute to make sure that the capacitors inside the device 

are discharged.

2. Press and hold down the grey „

TEST

” button on the device, and mean-

while connect it to the mains voltage. Do not release the „

TEST

” button 

until the LEDs on the front side of the device first start flashing alter

-

nately, then after a couple of seconds they become continuously illumi

-

nated for approximately 2 seconds together. After the  LEDs switch off, 
the device is in „

TEST

” mode, and it is ready for the verification of its 

operation.

3. The „

TEST

” mode of the wireless repeater inverts the signal sent from 

the thermostat to the receiver unit. When the thermostat sends a switch 
on command to the receiver unit and the sign of the heating/cooling 

equipment working appears on the display of the thermostat, the re

-

ceiver unit turns off. Similarly, after the switch off signal of the thermo

-

stat, the wireless repeater  sends a switch on signal to the receiver unit.

  The inverted operation shows that the signal repeater is working prop-

erly. With the help of this „

TEST

” mode, it is easy and fast to check the 

proper operation of the 

Q2RF

 wireless repeater even if it is close to the 

thermostat and the receiver unit.

4. To  finish  using  the  „

TEST

” mode, unplug the device from the mains 

voltage and wait approximately 1 minute to make sure that the capaci

-

tors are discharged. After this connect the device to the mains voltage 

again, and then it is ready to use.