the power supply (the controller itself, as well as the chain it controls
through the relayed exit).
- The device is to be installed only in places with limited access
with the assistance of an instrument or key and are accessible only to
the service personnel or a user who has passed the initial training.
- The wiring must be completed using double insulated wires.
- Disengagement tool must be provided for the electric installation
during the device’s installation and the needed safety is to be ensured
for the service provided.
- All connections to the relay’s outputs in the device must be
conducted with conductors with an insulation resistance not lower than that
of the insulated conductors of РVС Т 105°С.
- The device’s installation is conducted by the manufacturer’s
instructions and following the НD 60364-4-41 requirements, as well as the
national legislation.
- Installation of the controller in a way that the terminals are
positioned less than 5mm from the metal parts and the device’s surface, is
strictly forbidden.