3-5
Voice Interval Options
When the alert message is finished the weather station sends a termination data packet. Upon recipe
of this packet the WX-200 will turn off the speaker, line audio and repeater transmitter. The voice
synthesizer will continue to announce the alert until the time period has expired. Select the desired
voice alert options and click OK.
WX-200 Timer Settings
Click the [CLOCK] button to display the [WX-200 TIMER SELECT] Window. Timers include: Line Time-
out, Pre Voice Delay Timer, Voice Interval Timer and Relay Activation Delay Timer. Select the desired
times and click [OK].
Figure 3-9
Line Time-out Option
This timer selects the time the line audio and PTT outputs are active when an alert message is sent by
the weather station. A termination data packet is sent at the end of the alert message. Should the
weather station fail to send the termination data packet this timer will limit the alert transmission time.
Pre Voice Delay
This timer selects the delay between activation of the control relay and when the voice synthesizer
begins to speak.
Voice Interval Timer Option
Imbedded in the alert information packet is the time the warning or watch is in effect. The time is sent
in fifteen-minute increments for the first hour and thirty minute increments for the remaining time of
the alert. Once the alert message is finished, the red alert led on the front panel will continue to flash
and the WX-200 voice synthesizer will periodically key-up the repeater transmitter and announce the
nature of the alert. This timer sets the time between voice synthesizer announcements.
Relay Activation Delay
When the digital packet is decoded the relay disconnects the transmitter from the controller. If you
want to use the features of your repeater’s controller to send paging tones, alert tones or a custom
voice message announcement this disconnect must be delayed. Use this feature to select the delay.