BASIC WEIGHING AND TOTALISING 

 
The COMPULOAD CL6000 is designed to weigh a sea container when lifted by a Reach Stacker.  
This system has been setup to weigh in Dynamic Weighing Method (as the load is lowered). The 
COMPULOAD CL6000 has been calibrated using Lift Speed Compensation mode. This means 
that the CL6000 will weigh the load accurately at a wide range of boom lower speeds. If the 
operator lowers either to fast or to slow as to cause an inaccurate weight, the Compuload 

system will not allow the lift and display “Lift Speed Error”.

 The CL6000 will weigh the container 

as the magnet is lowered 

PAST 

the speed sensor.  

 

Basic Weighing 

 

 

1.

 

Before weighing the CL6000 should be checked to ensure that the EMPTY FRAME is 
reading ZERO. 

2.

 

Press the LOAD button to enable weighing. 

3.

 

With the frame empty, retract the BOOM fully and raise the frame to its maximum height.  

4.

 

If the screen says READY, lower the frame and a constant speed until the system shows a 
weight. If the screen shows RETRACT BOOM, the booms is not fully retracted and needs 
to be pulled in more. 

5.

 

Once a weight is displayed press and hold ZERO until 0.0 is displayed. 

6.

 

Press the LOAD button to enable weighing. 

7.

 

Attach the container and raise the frame to its maximum height. Lower the frame at a 
constant rate until the system shows a weight.  

8.

 

Enter the required information and press LOAD 

 
 
NOTE: - Pressing ESC will cancel that lift. 
 

 
 
 
 
 
 
 
 
 