background image

 

 

 

Hayetsira St. 17, Yokneam, Israel

   

Tel: +972-48-290-168 | Fax: +972-48-325-251 | www.fit-iot.com

 

 

 

 

 
 
 

www.fit-iot.com 

Page 17 of 19 

     

Tensor-I22 owner’s manual 

 

 

 

Connecting Tensor-I22 

 

1.

 

Before connecting Tensor-I22, please ensure that RAM and storage device are installed as detailed in the 
above sections. 

2.

 

Connect the display to Tensor-I22 using HDMI, or mini-DP cable. 

3.

 

Connect to Tensor-I22 USB keyboard and mouse. 

4.

 

Insert the DC plug into the Tensor-I22 DC-in jack. Rotate clockwise 90° to secure. 

5.

 

Slide into the power-supply the AC blade correct to your country and plug the power-supply into an AC-
outlet. The power button on Tensor-I22 should turn green, in a few seconds an image should appear on the 
display. 

6.

 

Connect Ethernet cable as needed. When link is established, the link LED on RJ45 should light. 

7.

 

If Tensor-I22 has WiFi adapter installed you will observe two SMA connectors (gold color screws) on the 
side panel. Connect the included antennas by screwing them clockwise onto the SMA connectors to enable WiFi 
communication. 

8.

 

If Tensor-I22 has LTE modem assembled - connect the included antennas by screwing them clockwise onto the 
SMA connectors to enable Cellular communication. 

 

 

Entering BIOS Setup

 

 

Turn off the Tensor-I22.

 

Turn on while holding down the Del key, until access into BIOS utility.

 

 

See 

https://fit-pc.com/wiki/index.php?title=Tensor-I22.

 

 

Installing and booting operating system

 

 

Please consul

https://fit-pc.com/wiki/index.php?title=Tensor-PC_Software 

for instructions. 

 

 

Содержание Tensor-I22

Страница 1: ...Owner s Manual Revision 1 2 Oct 2022 ...

Страница 2: ...ervicing that is not authorized by Compulab is not covered by your warranty Read and follow the safety instructions that came with the product CAUTION To avoid electrostatic discharge and prevent internal components damage from electrostatic discharge when touching computer or its parts ground yourself by using a wrist grounding strap or by periodically touching an unpainted metal surface such as ...

Страница 3: ...6 CONNECTORS LAYOUT 8 QUICK START GUIDE 9 MINIMUM REQUIREMENTS 9 IDENTIFYING TENSOR I22 CONFIGURATION 9 OPENING TENSOR I22 10 INSTALLING RAM 11 M 2 COOLING PLATE AND NVME SATA 12 OPTIONAL WIFI BT MODULE 14 CONNECTING TENSOR I22 17 ENTERING BIOS SETUP 17 INSTALLING AND BOOTING OPERATING SYSTEM 17 SERVICE 18 SUPPORT 18 WARRANTY 18 RMA 18 For more information and to obtain the latest revision of this...

Страница 4: ...Core processor Up to 64 GB DDR4 RAM NVMe M 2 SATA 2 5 storage Dual head 4K display Up to 4 Gbit Ethernet ports WiFi cellular communication USB 3 1 USB 2 0 audio optional Isolated serial GPIO ports Supports Windows 10 Windows 11 and Linux Can be extended with Tensor Element TEL All metal fanless housing 200 mm X 200 mm X 35 3 mm for standard housing Operating temperature range is from 40 C to 85 C ...

Страница 5: ...eless Connectivity M 2 Key E 2 For M 2 2230 module with Wi Fi 6E BT 5 2 M 2 Key B 2 For M 2 LTE 5G Optional TEL PCIEmini For mini PCIe module w micro SIM tray USB USB ports Up to 12 USB 3 1 2 0 ports Basic configuration 4x USB 3 1 on USB Type A Optional TEL USB3V4 Up to 2 additional 4x USB 3 1 on USB Type A Optional TEL USB2V4 Up to 2 additional 4x USB 2 0 on USB Type A Serial GPIO Serial GPIO por...

Страница 6: ... USB 2 0 LTE 5G modem M 2 Key E M 2 2230 or PCIe Gen 3 x1 USB 2 0 Wi Fi BT module M 2 Key M M 2 up to 2280 PCIe Gen 3 x4 SATA NVMe SATA storage AI TRIP1 Expansion TEL PCIe Gen 3 x4 2x PCIe TEL expansions for TRIP1 TRIP2 Expansion TEL PCIe Gen 3 x1 SATA TEL expansions for TRIP2 4 pin internal USB Expansion TEL USB 2 0 USB TEL expansions Optional TEL expansion modules TEL Description Max quantity Wh...

Страница 7: ...m Page 7 of 19 Tensor I22 owner s manual FT T SATA1 2x 2 5 SSD HDD 1 FT FT U POE2 2x Gbit Ethernet with PoE PSE 802 3at Type 1 by RJ45 1 TRIP1 FU FT W OPLN2 2 x SFP socket for optical GbE connection 1 TRIP1 FW Notes 1 This interface is also available in some quantity on the motherboard without a TEL ...

Страница 8: ...Hayetsira St 17 Yokneam Israel Tel 972 48 290 168 Fax 972 48 325 251 www fit iot com www fit iot com Page 8 of 19 Tensor I22 owner s manual Connectors layout Back view Front view ...

Страница 9: ...ll need RAM and storage device if not pre installed A display with HDMI or DisplayPort input HDMI or mini DisplayPort cable USB keyboard and mouse Identifying Tensor I22 configuration Tensor I22 configuration is detailed on the label attached to the bottom side of the computer Note Pay attention to RAM and storage If not installed Tensor I22 will not boot You will have to install these devices fir...

Страница 10: ...sor I22 You will need to open Tensor I22 in order to install RAM storage modem WiFi module RTC battery or extensions Required tool Phillips screwdriver To open Tensor I22 please follow these steps 1 Place Tensor I22 on a flat surface bottom up 2 Open the four screws using the Phillips screwdriver counter clock wise 3 Lift the bottom cover to remove it ...

Страница 11: ...90 168 Fax 972 48 325 251 www fit iot com www fit iot com Page 11 of 19 Tensor I22 owner s manual Installing RAM Tensor I22 can accept two SODIMM DDR4 modules Insert DDR4 SODIMM module and press it down until it is latching firmly on both sides ...

Страница 12: ... 42mm 52mm or 60mm and widths 22mm or 30mm All modules have to be fastened to the M 2 cooling plate To install NVMe SSD onto M 2 cooling plate 1 The red spacer is already assembled on the plate Move the red M 2 spacer according to the length of the M 2 NVMe SSD as depicted below Insert M 2 fastening screw but do not tighten 2 Place edge of M 2 NVMe SSD against the fastening screw a Press the NVMe ...

Страница 13: ...2 plate connectors against the appropriate sockets on the SBC a Press firmly on the plate until its connector edge is fully seated in the socket After correct positioning the holes in the plate align with the spacers on the board 5 Hold down the M 2 cooling plate and tighten the 3 panel screws 6 Use the Philips screwdriver for closing the bottom cover back 5 ...

Страница 14: ...168 Fax 972 48 325 251 www fit iot com www fit iot com Page 14 of 19 Tensor I22 owner s manual Optional WiFi BT Module WiFi module is not installed by default Installing WiFi BT module 1 Unscrew the side frame s as shown below 2 Remove the frame s ...

Страница 15: ...iot com Page 15 of 19 Tensor I22 owner s manual 3 Insert the WiFi BT antennas connectors into the appropriate holes in the frame s and tighten them by using wrench 4 Assembly back the frame and tighten it with screws 5 Remove the bottom cover by unscrewing 4 screws as shown in the picture above ...

Страница 16: ...16 of 19 Tensor I22 owner s manual 6 Insert the WiFi BT module into an appropriate socket in an angle 7 Press it down until latching the spacer 8 Tighten the fastening screw 9 Connect the wire edges of the antenna connectors to the appropriate connectors on the WiFi BT module Assembly back the bottom cover ...

Страница 17: ...n green in a few seconds an image should appear on the display 6 Connect Ethernet cable as needed When link is established the link LED on RJ45 should light 7 If Tensor I22 has WiFi adapter installed you will observe two SMA connectors gold color screws on the side panel Connect the included antennas by screwing them clockwise onto the SMA connectors to enable WiFi communication 8 If Tensor I22 ha...

Страница 18: ...riod of 60 months from the date of shipment Your sole remedy and Compulab s sole liability shall be for Compulab at its sole discretion to either repair or replace the defective product at no charge This warranty is void if the product has been altered or damaged by accident misuse or abuse RMA Keep the original package for shipping Please contact the seller of that Tensor I22 When issuing an RMA ...

Страница 19: ...ceiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Tensor I22 Manufacturer Compulab Ltd This device complies with Part 15 of the FCC Rules FCC ID PD98260NG IC ID IC 1000M 8260NG Intel Operation is subject ...