10.3.5 If further cleaning is required the cell needs to be cleaned in a mixture of one (1)
part Hydrochloric (Muriatic) Acid into four (4) parts water.
10.3.6
i
WARNING:
Chemical Hazard - When mixing acid with water, always add the
acid to the water, never add water to the acid. When using the acid ensure to use
rubber gloves and appropriate eye protection.
10.3.7 Connect the Cell Cleaning Plug to the end of the Cell Housing opposite the cable
using the Cell Cleaning Collar (see Figure 4). Place the Cell upright on a stable flat
surface with the Plug facing down.
10.3.8
Figure 4 -
Cell Cleaning Plug
10.3.9 Fill the Cell with the acid cleaning solution (3-5 cm from the top port) and clean until
the foaming action stops (typically 5 to 10 minutes). Rinse the cell with fresh water
and re-install into the plumbing line.
10.3.10 Note: Do not leave the cleaning solution in the Cell for more than 15 minutes as this
may cause damage to the Cell plates. Additionally excessive cleaning will reduce
the lifespan of the cell.