Страница 1: ...Copyright Component Engineering All Rights Reserved STRD 30C Digital Analog Sound Reader for Century Projectors...

Страница 2: ...it lens with its mounting bracket and the entire photocell assembly The sound drum rotary stabilizer and its ball bearings must also be removed temporarily NOTE The analog and digital sound pre amps a...

Страница 3: ...can get all of the optical pieces properly aligned exactly on radius with reference to the center line of the sound drum You are going to use the outboard sound drum bearing to accurately position the...

Страница 4: ...d screws The dual lens pre amp assembly should now be carefully eased onto the dowel pins in the adapter block and bolted in place It is a good idea to have the digital video cable already plugged ont...

Страница 5: ...s because the output of the LS 30 power supplies is clamped at a voltage too low to damage the LEDs The recommended wire size is 18 AWG The analog pre amp is powered by the 12 Volt bipolar supply in t...

Страница 6: ...tment of the two light sources The good news is that as already mentioned the two optical assemblies have been preset so that you have a beginning point Their focus and azimuth may not be exactly corr...

Страница 7: ...d the adjustment The other reason for this large contact area is that there is very good heat transfer from the LED itself right on down to the base casting of the sound head This means extra long lif...

Страница 8: ...running some digital film The following are optional but highly recommended A 486 class or better computer having a high speed 115kbs serial port and DRAS 10 software from Dolby A nine conductor male...

Страница 9: ...ng so that the splice doesn t come around too often The digital reader optics should be close enough for you to find a scope picture similar to this illustration The first thing is to adjust the digit...

Страница 10: ...ws and adjust the lateral position so that outer trace perf is off center by 1 5 major graticule to the left between goal posts A correct DRAS lateral position read out should be as close to zero as p...

Страница 11: ...ace and the lowest error rate on the processor display Large azimuth errors are seen as a tipping of the scope sprocket hole trace The axis will be the center of the displayed perf trace The DRAS azim...