MegaPulse 

IMPULSE TESTER 

Capacitor series A PF

 

 
 

Instruction Manual 

 

 

 
 

Содержание MegaPulse Capacitor A PF Series

Страница 1: ...MegaPulse IMPULSE TESTER Capacitor series A PF Instruction Manual...

Страница 2: ...ign and ergonomic front panel and represents the latest in high voltage impulse testing To fully appreciate all the features of your new instrument we suggest that you take a few moments to review thi...

Страница 3: ......

Страница 4: ...Megapulse Capacitor series A PF Specifications 7 Front and Rear Panel Features 8 Figure 1 Controls Indicators Connectors MegaPulse Capacitor series A PF Front Panel 8 Table 1 Controls Indicators Conn...

Страница 5: ...1...

Страница 6: ...re that high voltage is adept and creative at completing a path to ground Instructions should include a warning against any metal jewelry Operators should not allow others in the testing area especial...

Страница 7: ...d be set up to the left and in front of the equipment under test The equipment under test should be connected to the MegaPulse tester and then left alone by the operator After the operator is clear of...

Страница 8: ...s rated for the voltage involved and that the frequency response of the instrument and probe are capable of measuring the output waveform of the MegaPulse Impulse Tester A measuring instrument or prob...

Страница 9: ...F 1 User Manual 1 High Voltage Test Lead Red 00 HVL7R 3 feet 1 High Voltage Test Lead Black 00 HVL7B 3 feet 1 18 AWG AC Power Cord 70 101 1 TestMinder Optional User Manual 1 Software CD Megapulse Test...

Страница 10: ...l test house are regarded as meeting this requirement Fuse Replacement There is a user replaceable fuse F1 located on the rear panel of the instrument It is located behind a door in the Power Inlet Po...

Страница 11: ...point adjusted by frontal VOLTAGE knob or by PC optional Polarity Control Positive only Voltage Display 4 Digit LED Display Voltage Meter resolution 5V Duty Cycle 1 pulse every 10 seconds Line Voltage...

Страница 12: ...se of its controls indicators and connectors The front panel features of the MegaPulse are shown in Figure 1 and described in Table 1 The rear panel features of the MegaPulse are shown in Figure 2 and...

Страница 13: ...ross the output leads 7 TRIGGER indicator This Red indicator is lit to show that the tester can be trigger TRIGGER indicator is lit for 2 minutes after the CHARGE button is pressed TRIGGER indicator w...

Страница 14: ...d to the chassis of the MegaPulse and is referenced to earth ground as long as the MegaPulse is properly grounded Even though this jack is referenced to ground it should be treated as hazardous whenev...

Страница 15: ...d OFF 2 Fuse replacement warning Rating of power supply Specifies replacement fuse and required supply voltage 3 RS 232 Interface Optional Allow the communication between the tester and computer inter...

Страница 16: ...ect the ends of the test leads to a capacitor load of the range selected on the front panel knob plug your high voltage oscilloscope probe to the output leads as well Note that the RETURN lead is refe...

Страница 17: ...ce West USA is available Phone 800 748 6224 Hours 8 30 AM 4 30 PM Pacific Time Also available on our web site at www compwest com Contact Compliance West USA 650 Gateway Center Way Suite D San Diego C...

Страница 18: ...ll be corrected at no charge Mail the instrument post paid to the manufacturer Dated proof of purchase is required for all in warranty repairs The manufacturer is also available for calibration and or...

Страница 19: ...ation procedure must be performed by qualified personnel for more information contact Compliance West USA Voltage Stop Disable Keyboard Enable by Keyboard If the MegaPulse Capacitor series A PF tester...