AIR CLEANER / FILTERS
INSTALLATION INSTRUCTIONS AND HOMEOWNERS MANUAL FOR
COMPLETE COMFORT™ CABINET MODELS CCC14-23, CCC16-28, CCC20-28
COMPLETE COMFORT™ MEDIA
AIR CLEANER
506831-01
09/2011
General
Shipping and Packing List
Required Tools
Rules for Safe Installation
The Complete Comfort™ Media Air Cleaner uses an electro-
statically charged media to strain airborne particles as small as
0.3 microns with an efficiency rating of 85% or more. Unlike
other high efficiency 85% air cleaners, the Media Air Cleaner
uses no energy to operate.
The Complete Comfort™ Cabinet is shipped compact, and re-
quires minimal assembly. The Cabinet can be installed on the
furnace /air handler horizontally, or vertically, at the top, or at the
bottom, depending on the application (see Page 4 for applica-
tion diagrams). Complete Comfort™ Media Filter will last up to
one year (MERV 13 and MERV 10) depending on conditions
in the home. The cabinet is designed to house the CCF14-
10, CCF14-13, CCF16-10, CCF16-13, CCF20-10, CCF20-13,
boxed media filter purchases separately.
WARNING
Risk of property damage, injury, or death.
Installation, adjustments, alterations, service and
maintenance must be performed by a qualified
dealer.
CAUTION
Sharp Edges Hazard.
Equipment sharp edges can cause injuries.
Use protective gloves when grasping
equipment edges.
CAUTION
Risk of equipment damage and / or high energy
usage.
Dirty air filters will cause high-energy usage and
/or damage to the ventilation system.
Replace filters at recommended intervals.
Package 1 of 4 contains:
2 - Side panels
2 - Side rails
1 - Front panel
1 - Rear panel
1 - Doo
r
The following tools are required to attach the filter cabinet to
the furnace/ air handler:
Electric drill
1/4" (6mm) hex head tool
Tin snips
Screwdriver
Rule/tape measure
Gloves for sharp edge protection
Foil tape
1. Read this Owners Manual and Rules for Safe Opera-
tion carefully. Failure to follow these rules and instruc-
tions could cause a malfunction of filter or unsatis-
factory service.
2. Follow a regular service and maintenance schedule
for efficient operation.
3. Maximum static weight for cabinet - 400 lbs. (181 kg.)
506831-01