WLM54AG_1B.log

Timing Report ...

 

time taken for instrument setup 

 = 0.0

 

time taken for 11a cal   = 6.6

 

time taken for 11g cal   = 4.5

 

time taken for 11b cal   = 4.6

 

time taken for program eeprom 

 = 4.6

 

time taken for 11a target pwr ctl 

 = 3.0

 

time taken for 11a PER and RXSEN 

 = 6.9

 

time taken for 11g target pwr ctl 

 = 2.7

 

time taken for 11g PER and RXSEN 

 = 5.0

 

time taken for 11b target pwr ctl 

 = 3.3

 

time taken for 11b spectral mask 

 = 3.6

 

time taken for 11b PER and RXSEN 

 = 8.9

 

time taken for other things 

 = 6.0

 

Total test time 

 = 59.8 s  [1.0 min]

Wrote MAC address: 0080:483C:6061

###########################################################################
Cal Date: 2005/11/05, Cal Time: 14:04, Cal SSID: 0x2062, Cal Result: PASS
Cal wlan mac ID:  0080:483C:6061  

                    ########     ###     ######   ######              
                    ##     ##   ## ##   ##    ## ##    ##             
                    ##     ##  ##   ##  ##       ##                   
                    ########  ##     ##  ######   ######              
                    ##        #########       ##       ##             
                    ##        ##     ## ##    ## ##    ##             
                    ##        ##     ##  ######   ######              

###########################################################################

Page 6

Содержание WLM54AG

Страница 1: ...from calsetup txt Reading in Target Powers and CTL Info from calTrgtPwr_ar5006xs_mb62ag txt Plug in DUT Device Under Test Press any key to start or ESC to quit Waiting for other test set to finish Setting up Power Meter Setting up Spectrum Analyzer Setting up Attenuator using cal fixed gain for mode 11a from calsetup txt FG6 using cal fixed gain for mode 11b from calsetup txt FG6 using cal fixed g...

Страница 2: ...art RX PER Test in 11a mode 5180 MHz 54 Mbps 68 0 dBm SEN 99 0 24 1 99 5320 MHz 54 Mbps 68 0 dBm SEN 100 0 28 0 100 5600 MHz 54 Mbps 68 0 dBm SEN 100 0 30 0 100 5745 MHz 54 Mbps 68 0 dBm SEN 100 0 31 0 100 5825 MHz 54 Mbps 68 0 dBm SEN 99 0 31 1 99 Start Target Power Control Test in 11g mode FREQ 6Mbps 36Mbps 48Mbps 54Mbps Limits 1 0 1 5 dB measured target 2422 19 7 20 0 17 7 18 0 16 8 17 0 15 7 1...

Страница 3: ... 11 Mbps 68 0 dBm SEN 100 0 31 0 100 2472 MHz 11 Mbps 68 0 dBm SEN 100 0 31 0 100 Timing Report time taken for instrument setup 0 2 time taken for 11a cal 6 7 time taken for 11g cal 4 8 time taken for 11b cal 5 0 time taken for program eeprom 4 6 time taken for 11a target pwr ctl 2 9 time taken for 11a PER and RXSEN 7 2 time taken for 11g target pwr ctl 2 8 time taken for 11g PER and RXSEN 4 4 tim...

Страница 4: ...max pwr is 24 16 dBm ch 5600 max pwr is 22 29 dBm ch 5745 max pwr is 21 20 dBm ch 5825 max pwr is 20 39 dBm Collecting raw data for the adapter for mode 11g ch 2412 max pwr is 23 85 dBm ch 2442 max pwr is 23 57 dBm ch 2472 max pwr is 23 08 dBm Collecting raw data for the adapter for mode 11b ch 2412 max pwr is 24 66 dBm ch 2442 max pwr is 23 70 dBm ch 2472 max pwr is 24 06 dBm Start Target Power C...

Страница 5: ...pm Pwr 15 1 dB 2472 MHz 54 Mbps EVM 30 69 5 24 ppm Pwr 15 8 dB Start RX PER Test in 11g mode 2412 MHz 54 Mbps 68 0 dBm SEN 100 0 29 0 100 2442 MHz 54 Mbps 68 0 dBm SEN 100 0 29 0 100 2472 MHz 54 Mbps 68 0 dBm SEN 100 0 28 0 100 Start Target Power Control Test in 11b mode FREQ 1Mbps 5 5Mbps S 11Mbps L 11Mbps S Limits 1 0 1 5 dB measured target 2412 19 9 20 0 20 0 20 0 19 9 20 0 19 9 20 0 2442 19 9 ...

Страница 6: ...me taken for 11a PER and RXSEN 6 9 time taken for 11g target pwr ctl 2 7 time taken for 11g PER and RXSEN 5 0 time taken for 11b target pwr ctl 3 3 time taken for 11b spectral mask 3 6 time taken for 11b PER and RXSEN 8 9 time taken for other things 6 0 Total test time 59 8 s 1 0 min Wrote MAC address 0080 483C 6061 Cal Date 2005 11 05 Cal Time 14 04 Cal SSID 0x2062 Cal Result PASS Cal wlan mac ID...