Compcooler, keep your body cool and comfortable in harsh conditions.
6
The first time, remove the filler cap from top side,
add liquid to full by funnel,
connect the cooling
garment, turn on the pump and circulates the liquid from reservoir to cooling garment.
The second time,
keep running and allow the liquid cooling garment fill with water for 30-60
seconds (without cooling), refill again to full (maybe couple times, be patient), then tight the filler
cap.
Clean or distilled water is fine if ambient more than 1
℃
Deionized water for isolation request.
Anti-freeze liquid for ambient below 0
℃
.
DO NOT use salt water, caustic, corrosive or flammable fluids!
Refrigeration or Pre-cool Testing
User may turn on the system and start refrigeration, no pump circulation, temperature will down
in minutes. Cooling unit will be in standby mode once liquid temperature reaches to setting point.
Operation Processes
1.
Garment or Pad connection: Connect the extension tubing with liquid heating unit. Connect the
liquid cooling garment or pad at the other end.
O
nce you hear a click, it’s in position.
2.
Power connection:
turn on power switch and light the front panel.
The cooling unit will be in standby mode.
3.
Start cooling: user may press ON/OFF to start chiller, liquid temperature will go down to set
point in minutes.
pump is not working at this time.