background image

 

Compcooler, keep your body cool and comfortable in harsh conditions. 

 

 

The first time, remove the filler cap from top side, 

add liquid to full by funnel,

 connect the cooling 

garment, turn on the pump and circulates the liquid from reservoir to cooling garment.  
 
The second time, 

keep running and allow the liquid cooling garment fill with water for 30-60 

seconds (without cooling), refill again to full (maybe couple times, be patient), then tight the filler 
cap. 

 

Clean or distilled water is fine if ambient more than 1

 

Deionized water for isolation request. 
Anti-freeze liquid for ambient below 0

.  

DO NOT use salt water, caustic, corrosive or flammable fluids! 

 
 
Refrigeration or Pre-cool Testing 
User may turn on the system and start refrigeration, no pump circulation, temperature will down 
in minutes.  Cooling unit will be in standby mode once liquid temperature reaches to setting point.  
 

Operation Processes 

 

1.

 

Garment or Pad connection: Connect the extension tubing with liquid heating unit. Connect the 
liquid cooling garment or pad at the other end. 
O

nce you hear a click, it’s in position. 

 

 

2.

 

Power connection:

 turn on power switch and light the front panel. 

 
The cooling unit will be in standby mode. 
 

3.

 

Start cooling: user may press ON/OFF to start chiller, liquid temperature will go down to set 
point in minutes. 
pump is not working at this time. 
 

Содержание COMP-IRCU-110400

Страница 1: ...Compcooler keep your body cool and comfortable in harsh conditions 1 Indoor Refrigeration Chiller Unit Model COMP IRCU 110400 Rev A Operation Manual ...

Страница 2: ...oyees at Compcooler s state of the art manufacturing facility have been producing liquid heating cooling systems over 15 years Quality system ISO9001 and AS9100 registered facility Certifications for major items CE FCC UL PSE CB FDA Product Categories 1 ICE Water Circulation Systems 2 Micro Refrigeration Chiller Units 3 Liquid Heating Systems 4 Liquid Cooling Heating Garment and Pad 5 Customized C...

Страница 3: ...emperature at a comfortable range to against heat stress IRCU delivers 400W cooling capacity User can set up the temperature from 5 to 30 23 to 86 main board will control the ON OFF operation of refrigeration once circulation liquid reaches to set point temperature User may pre cool the unit and get the lowest temperature as he needs iceless cooling unit maintain free quiet operation This model is...

Страница 4: ...ower Consumption W 250 Refrigerant Type R134a Compressor Operation ON OFF Temp Control 5 to 30 23 86 Coolant Anti freeze liquid Yes Rotary Compressor Qty PC 1 Voltage V AC 110 or 220 Discharge CC 3 0 Fan Qty PC 2 Voltage V AC 110 or 220 Air Flow CFM 45 Pump Voltage V DC 24 Water flow L Min 5 Lift M 5 Power Connector Type 3 pins Operation Ambient Max 0 to 45 Storage Temp 20 to 70 Noise Max dBA 48 C...

Страница 5: ...nnect it with wall inlet plug 110V or 220V Please make sure the unit voltage before operation Cooling Garment Connection User may connect the chiller with Compcooler Cooling Vest or Cooling pad by quick release fittings One extension tubing was provided with chiller Chiller unit is compatible with all Compcooler garment if you want to try other brand garment please remove the quick fitting from ex...

Страница 6: ...id for ambient below 0 DO NOT use salt water caustic corrosive or flammable fluids Refrigeration or Pre cool Testing User may turn on the system and start refrigeration no pump circulation temperature will down in minutes Cooling unit will be in standby mode once liquid temperature reaches to setting point Operation Processes 1 Garment or Pad connection Connect the extension tubing with liquid hea...

Страница 7: ...ttom and open for dry Condenser clean To keep the system at optimum cooling capacity the condenser should be kept free of dust and dirt user may check and clean it if necessary Open the side panel and remove the fans use 50 100psi compressed air to clean the contamination Charging Refrigerant not recommend for uncertified operator If cooling capacity was decreased because of lack of refrigerant us...

Страница 8: ...n less than 18V 3 E3 High voltage protection more than 32V 4 P1 No liquid temp signal from sensor Cautions 1 Please confirm chiller voltage is 110V or 220V before connect power 2 Please do not turn ON OFF to run to stops system frequently within a short period it may affect the refrigeration system and significant enhance power consumption 3 Please do not block air inlet and outlet it may cause th...

Страница 9: ...om defects material and workmanship for warranty period not exceed one year from the date of shipment Compcooler agrees to correct for the original user of this product either by repair or at the manufacturer s election by replacement This warranty shall not apply if the defect or malfunction was caused by accident neglect unreasonable use improper service or other causes not arising out of defect...

Отзывы: