![Compass Arcus 07 151 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/compass/arcus-07-151/arcus-07-151_quick-start-manual_2646711007.webp)
E
Warning
:
–
Read the instructions for use carefully.
–
The charger is intended only for charging of lead accumulators.
–
Connect always the accumulator at first and only then the charger to 220 V mains.
–
Explosive gases are released - do not use naked flame during handling.
–
Ensure proper ventilation during charging.
–
Do not smoke during charging.
–
The charger is intended for use in interior areas only.
–
Protect against moisture. Keep out of reach of the children.
–
Do not open the charger. Do not shorten the cables.
–
If the charger casing or cable is damaged, the product may not be used.
–
Observe the principles of safe work when using the charger - risk of an electric shock.
07 151 - model 5 Amp (BC-5)
- t
echnical data
:
for accumulators:
12 V 10 - 60 Ah
rated input:
230 V ~ 50 Hz / 65 W
rated output:
12 V = 5A (ef.) / 3,5A (aritm.)
protection level:
IP 20
model:
KL-BC-AL1205EU-009
07 152 - model 8 Amp (BC-8)
- t
echnical data
:
for accumulators:
6 / 12 V 5 - 80 Ah
rated input:
230 V ~ 50 Hz / 85 W
rated output:
6 V = 0,85A (ef.) / 0,55A (aritm.)
12 V = 1,2A (ef.) / 0,8A (aritm.)
6 V = 8A (ef.) / 5,5A (aritm.)
12 V = 6,5A (ef.) / 4,5A (aritm.)
protection level:
IP 20
model:
KL-BC-AL1208EU-010
07 153 - model 10 Amp (BC-10)
- t
echnical data
:
for accumulators:
12 V 2 - 100 Ah
rated input:
230 V ~ 50 Hz / 134 W
rated output:
12 V = 10A (ef.) / 7,1A (aritm.)
protection level:
IP 20
model:
KL-BC-AL1210EU-012
LOW
LOW
HI
HI