Compaq ML330 - ProLiant - G3 Скачать руководство пользователя страница 5

Compaq ProLiant ML330 G2 Service Overview

5

Rev. 1.0

Page

 

5 of 20

Compaq Integrated ATA RAID Management Utility

This is an application installed from SmartStart that provides array monitoring and reporting by:

 

Monitoring the drives for failures

 

Sending alerts to the operating system.  (Compaq Insight Manager monitors the
system separately from the ATA RAID Management Utility.)

 

Initiating automatic rebuilds (either to an online spare or to the new drive.)

With integrated ATA RAID, the operating system can be installed on a pre-configured mirror
(RAID 1 volume).  Regardless of which drive fails, recovery of the mirror after replacing the
drive does not require user or operating system intervention.

ROM-Based Setup Utility (RBSU)

Like its predecessor, RBSU lets you view and establish server configuration settings during initial
system startup, as well as modify them after the server has been configured.  Because the file
operates from the system ROM (unlike previous configuration utilities stored on a hard drive):

 

The configuration parameters are always available, even if a drive fails.

 

It only takes 3 to 5 seconds to run the utility (vs. 3 to 5 minutes).

 

You can quickly install the latest version by flashing the system ROM with the latest
ROMPaq version.

In addition, RBSU checks each setting as it is made and immediately resolves possible conflicts
without bothering the administrator with an audible warning message.  And, because it is
embedded in the ROM, you can use the Compaq Remote Insight Lights-Out Edition to remotely
access and configure the system.

Compaq Remote ROM Flash Utility

This utility allows administrators to upgrade the system ROMs as well as the supported Compaq
Smart Array controllers on multiple servers from a remote location.  The ROM upgrades can
either be flashed individually or batched together to perform multiple ROM upgrades all at once.

Redundant ROM

If the server either loses power during a ROM flash or if the flash process is otherwise
interrupted, redundant ROM allows you to restart the system with the original ROM image.

Redundant ROM also allows you to use RBSU to switch between two ROM images for testing
and evaluation purposes.  Through RBSU, you can restart the server using the previous ROM
image if a new ROM flash doesn’t meet your expectations — eliminating the need to use the
ROMPAQ Flash Utility to fall back to the previous ROM version.

Automatic Server Recovery-2 (ASR-2)

Like ASR, ASR-2 resets the system in the event of a catastrophic operating system error and it
restarts the server within a predetermined amount of time after the system stops responding.  For
ASR-2, however, system administrators can set the interval in the RBSU.

Содержание ML330 - ProLiant - G3

Страница 1: ...iption 3 Features 3 Models 10 Option Kits 11 Spare Parts 12 Operating Systems 13 Drivers 13 Manageability Utilities 13 Installation Procedures 14 Processors 14 Memory 17 Integrated ATA RAID Troubleshooting Tips 17 Installing a Smart Array Controller 18 Service Considerations 18 References 19 Compaq ProLiant ML330 Generation 2 Service Overview Abstract This white paper describes the Compaq ProLiant...

Страница 2: ...s and other countries All other product names mentioned herein may be trademarks of their respective companies Compaq shall not be liable for technical or editorial errors or omissions contained herein The information in this document is provided as is without warranty of any kind and is subject to change without notice The warranties for Compaq products are set forth in the express limited warran...

Страница 3: ...nd 133MHz front side bus FSB Integrated 256KB 1 0GHz models or 512KB 1 13GHz models of L2 full speed cache 128MB of PC133 MHz ECC registered SDRAM DIMM standard expandable now to 4GB Integrated ATA RAID Configuration Utility with 0 1 and 0 1 capabilities Compaq Integrated Dual Channel Ultra ATA 100 Adapter ATA models or Integrated Dual Channel Wide Ultra3 SCSI Adapter SCSI models Either a non hot ...

Страница 4: ...lving the problems faced when the processor and heatsink were separated and then reattached An integrated VRM 8 5 powers the first processor a socketed 12V input VRM 8 5 powers the second 13 micron technology enables smaller less expensive chips that run faster and require less power Integrated ATA RAID Configuration Utility The Integrated ATA RAID Configuration Utility is a standard feature of Pr...

Страница 5: ...Paq version In addition RBSU checks each setting as it is made and immediately resolves possible conflicts without bothering the administrator with an audible warning message And because it is embedded in the ROM you can use the Compaq Remote Insight Lights Out Edition to remotely access and configure the system Compaq Remote ROM Flash Utility This utility allows administrators to upgrade the syst...

Страница 6: ... one for the SCSI models the other for the ATA models Other than the drive controllers and associated connectors the two boards are identical The SCSI models ship with only a SCSI drive controller the ATA models ship with only an ATA drive controller NMI Debug Button The NMI Debug button is located on the Server Feature Board NMI is a diagnostic mechanism that allows for crash dump files to be cre...

Страница 7: ...e drive LEDs In addition to the system LEDs on the front of the server and network controller LEDs on the back of the server the ML330 G2 now includes 15 diagnostic LEDs on the system board These LEDs indicate error conditions such as processor PPM or memory module failures Refer to the graphic and table on the following pages to determine what these lights indicate For detailed information on the...

Страница 8: ...rature is within an acceptable range 1 Off PPM 1 functioning 3 PPM 1 integrated failure Amber PPM 1 failed Off DIMM1 functioning 4 DIMM 1 failure Amber DIMM 1 failed Off DIMM 2 functioning 5 DIMM 2 failure Amber DIMM 2 failed Off DIMM 3 functioning 6 DIMM 3 failure Amber DIMM 3 failed Off DIMM 4 functioning 7 DIMM 4 failure Amber DIMM 4 failed Off PPM 2 functioning 8 PPM 2 failure Amber PPM 2 fail...

Страница 9: ...Fan is functioning 12 System fan failure Amber Fan is not installed or has failed Off Processor 2 functioning 13 Processor 2 failure Amber Processor 2 failed Off Processor 2 temperature normal 14 Processor 2 thermal Amber Thermal trip for processor 2 detected Verify Heatsink is properly installed Server fans are properly installed and working Ambient temperature is within an acceptable range 2 Off...

Страница 10: ... 234664 002 JVQ2 1 0GHz 20GB ML330T02 P1000 256KB 128 MB SCSI 234665 001 JVR1 1 0GHz None ML330T02 P1000 256KB 128 MB 18GB SCSI 234665 002 JVR2 1 0GHz 18 2GB ML330T02 P1133 512KB 128 MB ATA 225859 001 JVT1 1 133GHz None ML330T02 P1133 512KB 128 MB 20GB ATA 225859 002 JVT2 1 133GHz 20GB ML330T02 P1133 512KB 128 MB SCSI 225860 001 JVV1 1 133GHz None ML330T02 P1133 512KB 128 MB 18GB SCSI 225860 002 J...

Страница 11: ... 128277 B21 256 MB PC133 MHz Registered ECC SDRAM DIMM Memory Option Kit 128278 B21 512 MB PC133 MHz Registered ECC SDRAM DIMM Memory Option Kit 128279 B21 1024 MB PC133 MHz Registered ECC SDRAM DIMM Memory Option Kit 128280 B21 Hard Drive Kits Non Hot Plug 20 GB ATA 100 7 200 rpm Drive 1 231377 B21 40 GB ATA 100 7 200 rpm Drive 1 230534 B21 18 2 GB Wide Ultra3 SCSI 10 000 rpm Drive 1 142674 B21 3...

Страница 12: ...re Board ATA models 245246 001 Cable Kit ATA CD Diskette 253826 001 20 GB ATA 100 NHP hard drive 230699 001 40 GB ATA hard drive 232008 001 18 2 GB Wide Ultra3 hard drive 152191 001 Rack Enabling Kit 249443 001 ATA models only SCSI models only For a full listing of spare parts for the ProLiant ML330 Generation 2 Series of servers refer to Compaq ProLiant ML330 Generation 2 Server Maintenance and S...

Страница 13: ... new hardware that does not have driver support on all operating system installation media Use SmartStart and its Assisted Path feature to install your operating system and the latest driver support If you do not use SmartStart to install your operating system drivers for some of the new hardware are required These drivers as well as other option drivers ROM images and value add software can be do...

Страница 14: ...opulated before the CPU2 socket Table 5 Processor Installation Step Action 1 Verify that all critical data has been backed up 2 Ensure the server has the most current ROM version To update the ROM visit http www compaq com support files server us Caution Failure to flash the ROM before installing a new processor can cause system failure 3 Remove the Access Panel Refer to Setup and Installation Gui...

Страница 15: ...processor socket lever and then place the processor into the socket as shown below The guide posts and directional key marks on the socket must be aligned with the corresponding slots and marks on the processor 7 Lower the processor socket lever as shown below 8 Secure the heatsink retainer clip on the back of the processor to the socket as shown 1 2 ...

Страница 16: ... to the socket and then lock the processor in place by pressing down on the assembly clip lever Caution Applying too much pressure on the lever could break it Use care when performing this step 10 Install the corresponding PPM before powering up the server See Installing the PPM for Processor 2 11 Reinstall the fan baffle by reversing Step 4 1 2 ...

Страница 17: ...dels is a single 128MB DIMM Memory can be expanded one DIMM at a time in the four memory sockets provided Integrated ATA RAID Troubleshooting Tips Drive Connection If you have two drives connect one per channel The performance of the array is best with one drive per channel with both drives residing on the master connection of their channel Use the same type of drives or drives with similar speed ...

Страница 18: ...t back up your data When an array configuration changes previous data in that array is lost Use the table below to troubleshoot configuration and setup problems Table 7 Troubleshooting Configuration and Setup Problem Cause Solution Unexpected message e g Drives Missing or Configuration Mismatch Loose connection Switch off the system and verify all connections ATA cables and power cables Configurat...

Страница 19: ...2 001 or spare part number 176670 001 Compaq ProLiant ML330 Generation 2 Server Setup and Installation Guide First Edition August 2001 Part Number 234833 001 Compaq ProLiant ML330 Generation 2 G2 QuickSpecs DA 10523 Servers Troubleshooting Guide Part Number 161759 004 Quick Reference Guide ProLiant ML330 Generation 2 Note For online searches enter ML330 G2 to search for information about the ProLi...

Страница 20: ...Compaq ProLiant ML330 G2 Service Overview 20 Rev 1 0 Page 20 of 20 ...

Отзывы: