Table 2–2: Hardware Components Used in the Configuration Shown in
Figure 2–3
Callout Number
Description
1
BN38C HD68 to VHDCI cable
a b
2
H885-AA HD68 trilink connector
3
H879-AA HD68 terminator
4
BN21K or BN21L HD68 cable
b
aThe maximum length of the SCSI bus segment, including BN38C cable and internal device length, must
not exceed 25 meters.
bThe maximum length of the SCSI bus segment, including the combined length of the BN38C and BN21K
(or BN21L) cables, must not exceed 25 meters.
2.7.3.2 Cabling an HSZ70 to a DS-DWZZH-05 UltraSCSI Hub
To prepare the storage portion of a cluster using HSZ70 RAID array
controllers, follow these steps while referring to Figure 2–4 and Table 2–3:
1.
Install an H8861-AA trilink connector on each HSZ70 controller port
on the SCSI bus segment.
2.
Attach an H8863-AA terminator to the H8861-AA connector on the
HSZ70 controller that will be on the end of the SCSI bus segment.
3.
If there are two HSZ70 controllers, connect the two H8861-AA trilink
connectors on the controllers with a BN37A cable.
4.
Connect the DS-DWZZH-05 to the HSZ70 H8861-AA trilink with a
BN37A cable.
_____________________
Note
_____________________
The maximum length of a SCSI bus segment, including
cable and internal device SCSI bus length must not exceed
25 meters.
Figure 2–4 shows a sample configuration that uses a KZPBA-CB SCSI
adapter, a DS-DWZZH-05 UltraSCSI hub, and an HSZ70 RAID array
controller.
2–10 Using the DS-DWZZH-05 UltraSCSI Hub in a Cluster Configuration