![Compaq BL20p - ProLiant - G2 Скачать руководство пользователя страница 90](http://html.mh-extra.com/html/compaq/bl20p-proliant-g2/bl20p-proliant-g2_setup-and-installation-manual_2645071090.webp)
LEDs and Switches
Compaq ProLiant BL20p Server Blade Setup and Installation Guide
E-5
COMPAQ CONFIDENTIAL
Writer: Christine Portillo File Name: i-appe LEDs and Switches.doc
Codename: AvX Part Number: 307131-001 Last Saved On: 11/1/02 1:06 PM
Table E-2: Hot-Plug SCSI Hard Drive LED Status Combinations
(1) Activity
(2) Online (3)
Fault Means
On Off
Off
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is being accessed and is not configured as
part of an array.
On Flashing
Off
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is rebuilding or undergoing capacity
expansion.
Flashing Flashing
Flashing
Do not remove the drive. Removing a drive during
this process causes data loss.
The drive is part of an array being selected by the Array
Configuration Utility.
-Or-
The Options ROMPaq is upgrading the drive.
Off
Off
Off
OK to replace the drive online if a predictive failure alert
is received and the drive is attached to an array
controller.
The drive is not configured as part of an array.
-Or-
If this drive is part of an array, a powered-on controller
is not accessing the drive.
-Or-
The drive is configured as an online spare.
Off
Off
On
OK to replace the drive online.
The drive has failed and has been placed offline.
continued