![Compaq AlphaServer GS60E Скачать руководство пользователя страница 103](http://html.mh-extra.com/html/compaq/alphaserver-gs60e/alphaserver-gs60e_service-manual_2646511103.webp)
DECevent Error Log
4-41
Machine Check Logout Frame - 630/620
The TL6 Machine Check 630/620 logout frame provides error information to the
operating system error handler. When a fault is detected, PALcode enters a
error handler, captures the state of the processor and system, and builds a
logout frame. One frame is built for both processor and system detected errors
that are correctable. Machine check logout 630 contains EV6 CPU specific
errors registers while machine check logout 620 contains system specific error
registers.
63 … 48
47 … 32
31 … 16
15 … 00
Common Area:
R|S|D|C|
Frame Size
00
System Area Offset
CPU Area Offset
08
MCHK Frame Rev 8.
MCHK CODE
10
CPU Area:
ISTAT
18
DC_STAT
20
C_ADDR
28
DCI_SYNDROME
30
DCO_SYNDROME
38
C_STAT
40
C_STS
48
MM_STAT
50
63 … 48
47 … 32
31 … 16
15 … 00
System Area:
DOF_CNT
MISCR | WHAMI
58
TLBER
TLDEV
60
TLESR1
TLESR0
68
TLESR3
TLESR2
70
RESERVED
78
RESERVED
80
RESERVED
88